ASTM Selected Technical Papers
Exterior Insulation and Finish Systems (EIFS): Performance, Progress and InnovationAvailable to Purchase
By
Peter E. Nelson
Peter E. Nelson
Editor
Search for other works by this author on:
Bill Egan
Bill Egan
Editor
Search for other works by this author on:
ISBN:
978-0-8031-7615-7
No. of Pages:
296
Publisher:
ASTM International
Publication date:
2016

Fumed silica vacuum insulation panels (VIPs) have been known to provide excellent thermal insulation due to their extremely low thermal conductivity. VIPs are more fragile than conventional insulation and do not lend themselves to usage under typical jobsite conditions. An innovative way of incorporating VIPs into a 3-in.-thick wall cladding system was developed over a multiyear period through the U.S. Department of Energy (DOE) program DE-EE0003915. Initial performance testing of an exterior insulation and finish system (EIFS) utilizing VIPs was completed at Oak Ridge National Laboratories. Thermal performance was validated by using a heat flux meter (ASTM C518) and two hot box tests (ASTM C1363). Based on the results, THERMV © 5.2 and WUFI modeling were performed to determine optimum design. Field trials were completed on a retrofit project in a northern climate that resulted in delivering an R30 wall in a 3-in. thickness. The field trial further improved on the designs tested and modeled. The system uses drainage EIFS construction methods with the exception that the layout of insulation is engineered and sequenced. The wall system was then taken through further testing to ASTM E119, ASTM E330, NFPA 285, and NFPA 268 standards, to which all results were positive, rendering a code compliant commercial grade system. Thermal resistance performance values from R-24 to R-40 in a 3-in. overall panel thickness are demonstrated using Type 2 expanded polystyrene (EPS) insulation and varying the thickness of the VIP within the EPS. Installation of batt insulation within the steel stud cavities demonstrated an upgrade of R5. This high-efficiency wall cladding system will deliver top performance in a thin wall system not seen before in commercial construction in North America.

1.
Wegger
,
E.
,
Jelle
,
B.
,
Sveipe
,
E.
,
Grynning
,
S.
,
Gustavsen
,
A.
,
Baetens
,
R.
, and
Thue
,
J.
, “
Aging Effects on Thermal Properties and Service Life of Vacuum Insulation Panels
,”
Journal of Building Physics
, Vol.
35
, No.
2
,
2001
, p.128.
2.
ASTM C518
,
Standard Test Method for Steady State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
,
ASTM International
,
West Conshohocken, PA
,
2010
, www.astm.org
3.
Childs
,
K.
,
Stovall
,
T.
,
Biswas
,
K.
, and
Atchley
,
J.
,
Exterior Insulation Systems Containing Vacuum Insulation Panels Tested Using a Heat Flux Meter Apparatus, ORNL/TM-2012/ 276
,
Oak Ridge National Laboratory
,
Oak Ridge, TN
,
2012
.
4.
Seitz
,
A.
,
Carbary
,
L.
,
Childs
,
K.
,
Serino
,
R.
, and
Biswas
,
K.
, “
High Performance External Insulation and Finish System Incorporating Vacuum Insulation Panels—Foam Panel Composite and Hot Box Testing
,” presented at the ASTM Symposium on Next Generation Thermal Insulation, Jacksonville, FL, Oct. 23–24,
2013
.
5.
ASTM C1363–05
,
Standard Test method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot-Box Apparatus
,
ASTM International
,
West Conshohocken, PA
,
2005
, www.astm.org
6.
Biswas
,
K.
,
Desjarlais
,
A.
,
Childs
,
P.
, and
Atchley
,
J.
,
Steady State Thermal Performance Evaluation of Steel-Framed Walls with 78 % Coverage of Vacuum Insulated Panels Encapsulated Within an Exterior Insulation and Finish System, ORNL/TM-2011/77
,
Oak Ridge National Laboratory
,
Oak Ridge, TN
,
2011
.
7.
Biswas
,
K.
,
Stovall
,
T.
,
Desjarlais
,
A.
,
Childs
,
P.
, and
Atchley
,
J.
,
Steady State Thermal Performance Evaluation of Steel-Framed Walls with 94 % Coverage of Vacuum Insulated Panels Encapsulated Within an Exterior Insulation and Finish System, ORNL/TM-2012/438
,
Oak Ridge National Laboratory
,
Oak Ridge, TN
,
2012
.
8.
Dunlap
,
A.
and
Asava
,
R.
,
Hygrothermal Evaluation of Exterior Insulation Finish System (EIFS) with Encapsulated Vacuum Insulation Panels (VIP)
,
SmithGroupJJR
,
Detroit, MI
,
2013
.
9.
Simmler
,
H.
, “
Aging and Service Life of VIPs in Buildings
,” presented at the 7th International Vacuum Insulation Symposium, Dübendorf, Switzerland, Sept. 28–29,
2005
.
10.
Fallahi
,
A.
,
Misiopecki
,
C.
,
Shukla
,
N.
,
Watts
,
A.
, and
Kosny
,
J.
,
Whole House Testing and Analysis of a Building Retrofitted with VIP insulation and High Performance Windows
,
Fraunhofer Center for Sustainable Energy Systems (CSE)
,
Boston, MA
,
2014
.
11.
ASTM E330-02
,
Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference
,
ASTM International
,
West Conshohocken, PA
, 2002, www.astm.org
12.
ASTM E119-2
,
Standard Test Methods for Fire Tests of Building Construction and Materials
,
ASTM International
,
West Conshohocken, PA
,
2012
, www.astm.org
13.
NFPA 268
,
Standard Test Method for Determining Ignitability of Exterior Wall Assemblies Using a Radiant Heat Energy Source
,
NFPA
,
Quincy, MA
,
2012
.
14.
NFPA 285
,
Standard Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components
,
NFPA
,
Quincy, MA
,
2012
.
15.
Carbary
,
L.
,
Biswas
,
K.
,
Childs
,
K.
, and
Stovall
,
T.
, “
Thermal Performance of Exterior Insulation and Finish Systems Containing Vacuum Insulation Panels
,” presented at the ASHRAE Buildings XII Conference, Clearwater, FL, Dec. 1–5,
2013
.
16.
Carbary
,
L.
,
Perkins
,
L.
,
Preston
,
B.
,
Serino
,
R.
, and
Kosny
,
J.
, “
Contributing to Net Zero: High Energy Efficient EIFS Wall Systems
,” Report #1116737,
Dow Corning Corporation
,
Midland, MI
, 21014, http://www.osti.gov/scitech/servlets/purl/1116737
This content is only available via PDF.
You do not currently have access to this chapter.

or Create an Account

Close Modal
Close Modal