ASTM Selected Technical Papers
Modularity and Tapers in Total Joint Replacement Devices
By
A. Seth Greenwald, D.Phil.(Oxon)
A. Seth Greenwald, D.Phil.(Oxon)
Symposium Chairperson and STP Editor
1
Orthopaedic Research Laboratories
,
Cleveland, OH,
US
Search for other works by this author on:
Steven M. Kurtz, Ph.D.
Steven M. Kurtz, Ph.D.
Symposium Chairperson and STP Editor
2
Exponent, Inc.
,
Philadelphia, PA,
US
Search for other works by this author on:
Jack E. Lemons, Ph.D.
Jack E. Lemons, Ph.D.
Symposium Chairperson and STP Editor
3
University of Alabama at Birmingham
,
Birmingham, AL,
US
Search for other works by this author on:
William M. Mihalko, M.D., Ph.D.
William M. Mihalko, M.D., Ph.D.
Symposium Chairperson and STP Editor
4
Campbell Clinic Orthopaedics, University of Tennessee
,
Memphis, TN,
US
Search for other works by this author on:
ISBN:
978-0-8031-7627-0
No. of Pages:
463
Publisher:
ASTM International
Publication date:
2015

Wear and corrosion of implant metals have been associated with adverse tissue reactions and failures of total hips. However, the factors leading to component wear and corrosion, as well as the clinical effects of wear and corrosion, are not well understood. A visual inspection standard for taper corrosion and fretting, the Goldberg method, currently is used to quantify the amount of apparent corrosion damage present on an implant using a subjective score. We developed an approach to quantify the damage by creating digital microscopic images of the entire taper and trunnion surfaces, which enables an objective quantification of detailed wear and corrosion damage of the contacting surfaces, which we call the digital mosaic method (DMM). We compared the results of this new methodology to the Goldberg method and Anderson method (an expanded version of the Goldberg method). We examined the modular surfaces of ten retrieved metal-on-metal hip replacement systems. Each set of taper and trunnion surfaces were imaged and stitched into a composite image of the entire taper–trunnion surface. Three independent observers measured the surface area fraction of damage (wear or corrosion) for each surface, which in turn was compared with visual scores performed by independent observers on the same retrieved joints. To determine a measure of the intraobserver repeatability of the new method, a single reviewer measured the surface fraction of damage for the same set of explanted surfaces across different days, blinded to any previous specimen identification, with the image order randomized. The results of this study show that the DMM damage quantification correlates to the current visual scoring approaches (Goldberg and Anderson). The potential advantages to using this approach include better damage quantification, detailed analysis of specific locations, ability to identify matching damage locations on the two surfaces, and higher resolution of the contact area.

1.
Williams
,
D. F.
, in
Biocompatibility of Orthopedic Implants
,
Williams
D. F.
, Ed.,
CRC Press Inc.
,
Boca Raton, FL
,
1982
, Vol.
I
, p. 2.
2.
Mears
,
D. C.
, “
The Use of Dissimilar Metals in Surgery
,”
J. Biomed. Mater. Res.
, Vol.
9
, No.
4
,
1975
, pp. 133–148.
3.
Williams
,
D. F.
,
Black
,
J.
, and
Doherty
P. J.
, “
Second Consensus Conference on Definitions in Biomaterials
,”
Biomaterial-Tissue Interfaces, Advances in Biomaterials
, Vol.
10
,
Doherty
P. J.
,
Williams
R. L.
,
Williams
D. F.
 et al
, Eds.,
Elsevier
,
Amsterdam
,
1992
, pp. 525–533.
4.
Zuckerman
,
J. D.
,
Cavallo
,
R. J.
, and
Kummer
,
F. J.
, “
A Review of the Use of Modularity in Total Shoulder Arthroplasty
,”
Modularity of Orthopedic Implants, ASTM STP1301
,
Marlowe
D.
,
Parr
J.
, and
Mayor
M.
, Eds.,
ASTM International
,
West Conshohocken, PA
,
1997
, pp. 5–18.
5.
Urban
,
R. M.
,
Jacobs
,
J. L.
,
Gilbert
,
J. L.
,
Rice
,
S. B.
,
Jasty
,
M.
,
Bragdon
,
C. R.
, and
Galante
,
J. O.
, “
Characterization of Solid Products of Corrosion Generated by Modular-Head Femoral Stems of Different Designs and Materials
,”
Modularity of Orthopedic Implants, ASTM STP1301
,
Marlowe
D.
,
Parr
J.
, and
Mayor
M.
, Eds.,
ASTM International
,
West Conshohocken, PA
,
1997
, pp. 33–44.
6.
Gilbert
,
J. L.
and
Jacobs
,
J. J.
, “
The Mechanical and Electrochemical Processes Associated with Taper Fretting Crevice Corrosion: A Review
,”
Modularity of Orthopedic Implants, ASTM STP1301
,
Marlowe
D.
,
Parr
J.
, and
Mayor
M.
, Eds.,
ASTM International
,
West Conshohocken, PA
,
1997
, pp. 45–59.
7.
McLean
,
T. W.
and
Lambert
,
R. D.
, “
Test Method for the Assessment of Fretting at the Femoral Head and Neck Taper Interface
,”
Modularity of Orthopedic Implants, ASTM STP1301
,
Marlowe
D.
,
Parr
J.
, and
Mayor
M.
, Eds.,
ASTM International
,
West Conshohocken, PA
,
1997
, pp. 104–113.
8.
Schmidt
,
A. H.
,
Loch
,
D. A.
,
Bechtold
,
J. E.
, and
Kyle
,
R. F.
, “
Assessing Morse Taper Function: The Relationship between Impaction Force, Disassembly Force, and Design Variables
,”
Modularity of Orthopedic Implants, ASTM STP1301
,
Marlowe
D.
,
Parr
J.
, and
Mayor
M.
, Eds.,
ASTM International
,
West Conshohocken, PA
,
1997
, pp. 114–126.
9.
Richter
,
H. G.
,
Willmann
,
G.
,
Wimmer
,
M.
, and
Osthues
,
F. G.
, “
Influence of the Ball/Stem-Interface on the Load Bearing Capability of Modular Total Hip Endoprostheses
,”
Modularity of Orthopedic Implants, ASTM STP1301
,
Marlowe
D.
,
Parr
J.
, and
Mayor
M.
, Eds.,
ASTM International
,
West Conshohocken, PA
,
1997
, pp. 127–133.
10.
Bhambri
,
S. K.
and
Gilbertson
,
L. N.
, “
Fretting Corrosion Fatigue Study of Modular Joints in Total Hip Replacements by Accelerated In Vitro Testing
,”
Modularity of OrthopedicImplants, ASTM STP1301
,
Marlowe
D.
,
Parr
J.
, and
Mayor
M.
, Eds.,
ASTM International
,
West Conshohocken, PA
,
1997
, pp. 146–156.
11.
Goldberg
,
J. R.
,
Buckley
,
C. A.
,
Jacobs
,
J. J.
, and
Gilbert
,
J. L.
, “
Corrosion Testing of Modular Hip Implants
,”
Modularity of Orthopedic Implants, ASTM STP1301
,
Marlowe
D.
,
Parr
J.
, and
Mayor
M.
, Eds.,
ASTM International
,
West Conshohocken, PA
,
1997
, pp. 157–176.
12.
Brown
,
S. A.
,
Abera
,
A.
,
D'Onofrio
,
M.
, and
Flemming
,
C.
, “
Effects of Neck Extension, Coverage, and Frequency on the Fretting Corrosion of Modular THR Bore and Cone Interface
,”
Modularity of Orthopedic Implants, ASTM STP1301
,
Marlowe
D.
,
Parr
J.
, and
Mayor
M.
, Eds.,
ASTM International
,
West Conshohocken, PA
,
1997
, pp. 189–198.
13.
Jani
,
S.
,
Sauer
,
W.
,
McLean
,
T.
,
Lambert
,
R.
, and
Kovacs
,
P.
, “
Fretting Corrosion Mechanisms at Modular Implant Interfaces
,”
Modularity of Orthopedic Implants, ASTM STP1301
,
Marlowe
D.
,
Parr
J.
, and
Mayor
M.
, Eds.,
ASTM International
,
West Conshohocken, PA
,
1997
, pp. 211–225.
14.
Kovacs
,
P.
,
Davidson
,
J. A.
, and
Daigle
,
K.
, “
Correlation Between the Metal Ion Concentration and the Fretting Wear Volume of Orthopaedic Implant Metals
,” in
Particulate Debris from Medical Implants: Mechanisms of Formation and Biological Consequences, ASTM STP1144
,
St. John
K. R.
, Ed.,
ASTM International
,
West Conshohocken, PA
,
1992
, pp. 160–176.
15.
Kovacs
,
P.
, “
In Vitro Studies on the Electrochemical Behavior of Carbon-Fiber Composites
,”
Composite Materials for Implant Applications in the Human Body: Characterization and Testing, ASTM STP1178
,
Jamison
R.
and
Gilbertson
L.
, Eds.,
ASTM International
,
West Conshohocken, PA
,
1993
, pp. 41–52.
16.
Kovacs
,
P.
and
Davidson
,
A.
, “
Chemical and Electrochemical Aspects of the Biocompatibility of Titanium and Its Alloys
,”
Medical Applications of Titanium and Its Alloys: The Material and Biological Issues, ASTM STP1272
,
Brown
S.
and
Lemons
J.
, Eds.,
ASTM International
,
West Conshohocken, PA
,
1996
, pp. 163–178.
17.
Bolland
,
B. J.
,
Culliford
,
D. J.
,
Langton
,
D. J.
,
Millington
,
J. P.
,
Arden
,
N. K.
, and
Latham
,
J. M.
, “
High Failure Rates with a Large-Diameter Hybrid Metal-on-Metal Total Hip Replacement
,”
J. Bone Joint Surg. Br.
, Vol.
93
, No.
5
,
2011
, pp. 608–615.
18.
Langton
,
D. J.
,
Jameson
,
S. S.
,
Joyce
,
T. J.
,
Gandhi
,
J. N.
,
Sidaginamale
,
R.
,
Mereddy
,
P.
,
Lord
,
J.
, and
Nargol
,
A. V.
, “
Accelerating Failure Rate of the ASR Total Hip Replacement
,”
J. Bone Joint Surg. Br.
, Vol.
93
, No.
8
,
2011
, pp. 1011–1016.
19.
Langton
,
D. J.
,
Sidaginamale
,
R.
,
Lord
,
J. K.
,
Nargol
,
A. V. F.
, and
Joyce
,
T. J.
, “
Taper Junction Failure in Large-Diameter Metal-on-Metal Bearings
,”
Bone Joint Res.
, Vol.
1
, No.
4
,
2012
, pp. 56–63.
20.
Fricka
,
K. B.
,
Ho
,
H.
,
Peace
,
W. J.
, and
Engh
,
C. A.
, Jr.
, “
Metal-on-Metal Local Tissue Reaction Is Associated with Corrosion of the Head Taper Junction
,”
J. Arthroplasty
, Vol.
27
, No.
8 (Suppl. 1)
,
2012
, pp. 26–31.
21.
Goldberg
,
J. R.
,
Gilbert
,
J. L.
,
Jacobs
,
J. J.
,
Bauer
,
T. W.
,
Paprosky
,
W.
, and
Leurgans
,
S.
, “
A Multicenter Retrieval Study of the Taper Interfaces of Modular Hip Prostheses
,”
Clin. Orthop. Relat. Res.
, Vol.
401
,
2002
, pp. 149–161.
22.
Gilbert
,
J. L.
,
Buckley
,
C. A.
, and
Jacobs
,
J. J.
, “
In Vivo Corrosion of Modular Hip Prosthesis Components in Mixed and Similar Metal Combinations. The Effect of Crevice, Stress, Motion, and Alloy Coupling
,”
J. Biomed. Mater. Res.
, Vol.
27
, No.
12
,
1993
, pp. 1533–1544.
23.
Kurtz
,
S. M.
,
Kocagoz
,
S. B.
,
Hanzlik
,
J. A.
,
Underwood
,
R. J.
,
Gilbert
,
J. L.
,
MacDonald
,
D. W.
,
Lee
,
G. C.
,
Mont
,
M. A.
,
Kraay
,
M. J.
,
Klien
,
G. R.
,
Parvizi
,
J.
, and
Rimnac
,
C. M.
, “
Do Ceramic Femoral Heads Reduce Taper Fretting Corrosion in Hip Arthroplasty? A Retrieval Study
.”
Clin. Orthop. Relat. Res.
, Vol.
471
, No.
10
,
2013
, pp. 3270–3282.
This content is only available via PDF.
You do not currently have access to this chapter.
Close Modal

or Create an Account

Close Modal
Close Modal