Skip to Main Content
Skip Nav Destination
ASTM Selected Technical Papers
Durability of Building and Construction Sealants and Adhesives
By
A Wolf
A Wolf
1
Dow Corning GmbH.
?
Wiesbaden
Germany
Symposium Chairman and Editor
Search for other works by this author on:
ISBN-10:
0-8031-3480-0
ISBN:
978-0-8031-3480-5
No. of Pages:
419
Publisher:
ASTM International
Publication date:
2004

The design of conventional glass façades in Germany is typically based on the extensive use of point supports that keep the glass panels in position and which provide the load transfer of the façade. Besides the aesthetic disadvantage of discrete elements being visible in the glass façade, the application of point supports leads to highly concentrated stress regions substantially affecting sizing and durability of the façade components. In order to overcome these limitations, a new approach has been chosen for the design of the glass façade of the Herz Jesu Church, Munich. One peculiarity of the overall glass façade of this box-shaped building consists in horizontal and vertical glass beams used for the support of the façade. Silicone adhesives bond steel stringers along the main edges of the horizontal and vertical glass beams in order to establish load paths between beams and façade. The hereby-realized bonding design offers special features being favorable for the durability of the building. Load carrying capacities have been provided by line-type connections, substantially reducing stress concentrations. Major attention has been given to the geometric layout of the bonding. Thus, detailed finite element (FE) analysis has guided the careful selection of an adequate channel cross section for the stringers. The design philosophy of the bonding is characterized by a small exposed surface of the silicone adhesive, offering only a very small area of attack for environmental degradation. Additionally, the exposed surface is only stressed at a low level avoiding the critical combination of highly loaded areas exposed to aggressive environmental conditions. Furthermore, two principal load paths (tension and shear) are established, leading to a fail-safe design principle of the bonding. These key considerations provide major contributions to the high durability design of the glass façade bonding.

1.
Hagl
,
A.
, “
Synthese aus Glas und Stahl: Die Herz-Jesu-Kirche München
,” Stahlbau, Vol.
71
, No. 7,
Ernst & Sohn Verlag
,
Berlin, Germany
,
2002
.
2.
Kinloch
,
A. J.
(Ed.),
Durability of Structural Adhesives
,
Elsevier Applied Science Publishers Ltd.
,
London, United Kingdom
,
1983
.
3.
Forschungsund Materialprüfungsanstalt (FMPA) Baden Württemberg
, “
Untersuchung des Adhäsionsverlustes von Silikonklebern durch Wasserlagerung, Bericht: 25-13035-1
,”
Fraunhofer IRB Verlag
,
Stuttgart, Germany
,
1996
.
4.
Schneider
,
K. J.
(Ed.),
Bautabellen für Ingenieure
,
Werner Verlag
,
Düsseldorf, Germany
,
1998
.
5.
Sedlacek
,
G.
,
Blank
,
K.
,
Laufs
,
W.
, and
Guesgen
,
J.
,
Glas im Konstruktiven Ingenieurbau
,
Ernst & Sohn Verlag
,
Berlin, Germany
,
1999
.
6.
Dow Corning GmbH Deutschland
,
Hochwertige Lösungen für das Baugewerbe
,
Dow Corning Corporation
,
Wiesbaden, Germany
,
2000
.
7.
Wolf
,
A. T.
, and
Descamps
,
P.
, “
Determination of Poisson's Ratio of Silicone Sealants from Ultrasonic and Tensile Measurements
,” Performance of Exterior Building Walls, ASTM STP 1422,
Johnson
P. G.
, Ed.,
ASTM International
,
West Conshohocken, PA
,
2002
.
This content is only available via PDF.
You do not currently have access to this chapter.
Close Modal

or Create an Account

Close Modal
Close Modal