Skip to Main Content
Skip Nav Destination
ASTM Selected Technical Papers
Crosslinked and Thermally Treated Ultra-High Molecular Weight Polyethylene for Joint ReplacementsAvailable to Purchase
Editor
SM Kurtz
SM Kurtz
Search for other works by this author on:
RA Gsell
RA Gsell
Search for other works by this author on:
J Martell
J Martell
Search for other works by this author on:
ISBN-10:
0-8031-3474-6
ISBN:
978-0-8031-3474-4
No. of Pages:
272
Publisher:
ASTM International
Publication date:
2004

Recently, a knee prosthesis containing an electron beam irradiated (58 – 72 kGy, nominal dose of 65 kGy), melt-annealed, highly crosslinked UHMWPE (HXPE) tibial insert has been developed. In the present study, the wear and delamination resistance of the HXPE tibial insert and its fatigue performance under a posterior loading condition have been evaluated against its conventional gamma-sterilized UHMWPE counterpart (37kGy, in nitrogen). The test methodologies used were newly developed with the aim to evaluate this new material under severe testing conditions.

In comparison to the gamma controls, the HXPE inserts: (a) wore significantly less (achieving wear reductions of 81% and 73% over 5 and 20 million cycles, respectively); (b) exhibited significantly improved delamination resistance; and (c) exhibited significantly improved posterior loading fatigue resistance.

1.
Horev
,
A.D.
and
Weinstein
,
M.
, “
Orthopaedic Industry Update
,”
J. P. Mogan Securities Industry Update
, June 28th, 2002, N.Y.
2.
McKellop
,
H.A.
,
Shen
,
F.W.
,
Bin
,
L.
,
Campbell
,
P
. and
Salovey
,
R.
, “
Development of an Extremely Wear-Resistant Ultra-High Molecular Weight Polyethylene for Total Hip Replacements
,”
Journal of Orthopedic Research
, vol.
17
,
1999
, pp. 157–167.
3.
Muratoglu
,
O.K.
,
Bragdon
,
C.R.
,
O'Connor
,
D.O.
,
Jasty
,
M.
and
Harris
,
W.H.
, “
A Novel Method of Cross-Linking Ultra-High Molecular Weight Polyethylene to Improve Wear, Reduce Oxidation and Retain Mechanical Properties
,”
Journal of Arthroplasty
, vol.
16
,
2001
, pp. 149–160.
4.
Wang
,
A.
,
Polineni
,
V.K
,
Essner
,
A.
,
Sun
,
D.C.
,
Stark
,
C.
and
Dumbleton
,
J.H.
, “
Effect of Radiation Dosage on the Wear of Stabilized UHMWPE Evaluated by Hip and Knee Joint Simulators
,”
Transactions of the 23rd Society Congress on Biomaterials
,
1997
, p. 394.
5.
Laurent
,
M.P.
,
Yao
,
J.Q.
,
Bhambri
,
S.K.
,
Gsell
,
R.A.
,
Gilbertson
,
L.N.
,
Swarts
,
D.F.
and
Crowninshield
,
R.D.
, “
High Cycle Wear of Highly Crosslinked UHMWPE Acetabular Liners Evaluated in a Hip Simulator
,”
Transaction of the 46th Annual Meeting of Orthopaedic Research Society
,
2000
, p. 567.
6.
Oonishi
,
H.
,
Saito
,
M.
and
Kadoya
,
Y.
, “
Wear of High Dose Gamma Irradiated Polyethylene in Total Joint Replacement — Long-Term Radiological Evaluation
,”
Transaction of the 44th Annual Meeting of Orthopaedic Research Society
,
1998
, p. 97.
7.
Wroblewski
,
B.M.
,
Siney
,
P.D.
and
Fleming
,
P.A.
, “
Low-Friction Arthroplasty of the Hip Using Alumina Ceramic and Crosslinked Polyethylene
,”
Journal of Bone and Joint Surgery (Br)
, vol.
81(B)
,
1991
, pp. 54–55.
8.
Grobbelaar
,
C.J.
,
Du Plessis
,
T.A.
and
Marais
,
F.
, “
The Radiation Improvement of Polyethylene Prosthesis
,”
Journal of Bone and Joint Surgery (Br)
, vol.
60(B)
,
1978
, pp. 370–374.
9.
Pooley
,
C.M.
and
Tabor
,
D.
, “
Friction and Molecular Structure: The Behaviour of Some Thermoplastics
,”
Proceedings of the Royal Society of London
 0370-1662, vol.
329
,
1972
, pp. 251–258.
10.
Wang
,
A.
,
Sun
,
D.C.
,
Edwards
,
B.
,
Sokol
,
M.
,
Essner
,
A.
,
Polineni
,
V.K.
,
Stark
,
C.
and
Dumbleton
,
J.H.
, “
Orientation Softening in the Deformation and Wear of Ultra-High Polyethylene
,”
Wear
 0043-1648, vol.
203/204
,
1997
, pp. 230–241.
11.
Johnson
,
T.S.
,
Laurent
,
M.P.
and
Yao
,
J.Q.
, “
The Tibiofemoral Cross-Motion Pattern and Its Effect on the Wear of a Prosthetic Knee
,”
Transaction of the 28th Annual Meeting of Society for Biomaterials
,
2002
, p. 191.
12.
Ramamurti
,
B.
,
Estok
,
D.M.
,
Muratoglu
,
O.K.
and
Harris
,
W.H.
, “
Comparison of Paths Traced by Points on the Polyethylene Surface in THA and TKA
,”
Transaction of the 45th Annual Meeting of Orthopedic Research Society
,
1999
, p. 823.
13.
Williams
,
I.R.
,
Mayor
,
M.B.
and
Collier
,
J.P.
, “
The Impact of Sterilization Method on Wear in Knee Arthroplasty
,”
Clinical Orthopedics and Related Research
, vol.
356
,
1998
, pp. 170–180.
14.
Won
,
C.H.
,
Rimnac
,
C.
,
Goldberg
,
V.
,
Kraay
,
M.
and
Rohatgi
,
S.
, “
Effect of Resin Type and Manufacturing Method on Wear Damage Modes in MG I and MG II UHMW Polyethylene Tibial Components
,”
Transaction of the 25th Annual Meeting of the Society for Biomaterials
,
1999
, p. 302.
15.
Bhambri
,
S.
,
Gsell
,
R.
,
Kirkpatrick
,
L.
,
Gilbertson
,
L.N.
,
Swarts
,
D.F.
,
Blanchard
,
C.R.
and
Crowninshield
,
R.D.
, “
The Effect of Aging on Melt-Annealed CrossLinked Polyethylene
,”
Transaction of the 28th Annual Meeting of the Society for Biomaterials
,
2002
, p. 58.
16.
Bartel
,
D.L.
,
Nicknell
,
V.L.
and
Wright
,
T.M.
, “
The Effect of Conformity, Thickness and Material on Stresses in Ultra-High Molecular Weight Components for Total Joint Replacement
,”
Journal of Bone and Joint Surgery (Am)
, vol.
68A
,
1986
, pp. 1041–1051.
17.
Johnson
,
T.S.
,
Laurent
,
M.P.
,
Yao
,
J.Q.
and
Gilbertson
,
L.N.
, “
The Effect of Displacement Control Input Parameters on Tibiofemoral Prosthetic Knee Wear
,”
Wear
 0043-1648, vol.
250
,
2001
, pp. 222–226.
18.
Ramamurti
,
B.S.
,
Bragdon
,
C.R.
,
O'Connor
,
D.O.
,
Lowenstein
,
J.D.
,
Jasty
,
M.
,
Estok
,
D.M.
and
Harris
,
W.H.
, “
Loci of Movement of Selected Points on The Femoral Head During Normal Gait: Three-Dimensional Computer Simulation
,”
Journal of Arthroplasty
, vol.
11
,
1996
, pp. 845–852.
19.
Edidin
,
A.A.
,
Muth
,
J.
,
Spiegelberg
,
S.
and
Schaffner
,
S.
, “
Sterilization of UHMWPE in Nitrogen Prevents Oxidative Degradation for More Than Ten Years
,”
Transaction of the 46th Annual Meeting of Orthopedic Research Society
,
2000
, p. 1.
20.
Hardaker
,
C.S.
,
Fisher
,
J.
,
Issac
,
G.
,
Stone
,
M.
and
Older
,
J.
, “
Quantification of the Effect of Shelf and In Vivo Aging on the In Vivo and In Vivo Wear Rates of a Series of Retrieved Charnley Acetabular Cups
,”
European Society of Biomaterials
,
2000
.
21.
Edidin
,
A.A.
,
Villaraga
,
M.L.
,
Herr
,
M.P.
,
Ciccarelli
,
L.
,
Hozack
,
W.
,
Turner
,
W.
and
Kurtz
,
S.M.
, “
Relationship between Clinical Performance and Mechanical behavior of Retrieved UHMWPE Acetabular Liners
,”
Transactions of the 28th Annual Meeting of the Society for Biomaterials
,
2002
, p. 25.
This content is only available via PDF.
You do not currently have access to this chapter.

or Create an Account

Close Modal
Close Modal