Skip to Main Content
Skip Nav Destination
ASTM Selected Technical Papers
Crosslinked and Thermally Treated Ultra-High Molecular Weight Polyethylene for Joint Replacements
Editor
SM Kurtz
SM Kurtz
Search for other works by this author on:
RA Gsell
RA Gsell
Search for other works by this author on:
J Martell
J Martell
Search for other works by this author on:
ISBN-10:
0-8031-3474-6
ISBN:
978-0-8031-3474-4
No. of Pages:
272
Publisher:
ASTM International
Publication date:
2004

Released wear debris of implants causes local inflammation of the host tissue if it is in a phagocytosable size. The purpose of this study was to compare particle size, shape, and number of three different types of UHMWPE. After wear testing, particles were isolated from the serum and analyzed using SEM. The parameters ‘equivalent circle diameter’ (ECD) and ‘equivalent shape ratio’ (ESR) were determined. Most of the generated debris was sub-micron in size. Classifying the particles into size groups demonstrated a non-linear correlation between size and shape for all three types of polyethylene: small particles were more round, large particles were more elongated. Based on this relationship, the generated number of particles and their total surface area were estimated and compared with calculations based on size alone.

1.
McKellop
,
H. A.
,
Campbell
,
P.
,
Park
,
S.-H.
,
Schmalzried
,
T. P.
,
Grigoris
P.
,
Amstutz
,
H. C.
and
Sarmiento
,
A.
, “
The Origin of Submicron Polyethylene Wear Debris in Total Hip Arthroplasty
”,
Clinical Orthopaedics and Related Research
, Vol.
311
,
1995
, pp. 3–20.
2.
Glant
,
T.T.
,
Jacobs
,
J.J.
,
Molnar
,
G.
,
Shanbhag
,
A.S.
,
Valyon
,
M.
, and
Galante
,
J.O.
, “
Bone Resorption Activity of Particulate stimulated Macrophages
,”
Journal of Bone and Mineral Research
, Vol
8
,
1993
, pp. 1071–1079.
3.
Shanbhag
,
A. S.
,
Jacobs
,
J. J.
,
Black
,
J.
,
Galante
,
J. O.
, and
Glant
,
T. T.
, “
Macrophage/particle interactions: effect of size, composition and surface area
”,
Journal of Biomedical Material Research
, Vol.
28
,
1994
, pp. 81–90.
4.
Ingham
,
E.
, and
Fisher
,
J.
, “
Biological reactions to wear debris in total joint replacement
”,
Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine
, Vol.
214
,
2000
, pp. 21–37.
5.
Jacobs
,
J. J.
,
Shanbhag
,
A. S.
,
Glant
,
T. T.
,
Black
,
J.
, and
Galante
,
J. O.
, “
Wear Debris in Total Joint Replacements
,”
Journal of the American Academy of Orthopedic Surgery
, Vol.
2
,
1994
, pp. 212–220.
6.
McKellop
,
H.
,
Shen
,
F. W.
,
Lu
,
B.
,
Campbell
,
P.
, and
Salovey
,
R.
, “
Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements
,”
Journal of Orthopedic Research
, Vol.
17
(
2
),
1999
, pp. 157–167.
7.
Muratoglu
,
O. K.
,
Bragdon
,
C. R.
,
O'Connor
,
D. O.
,
Jasty
,
M.
,
Harris
,
W. H.
,
Gul
,
R.
, and
McGarry
,
F.
, “
Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE)
,”
Biomaterials
 0142-9612, Vol.
20
,
1999
, pp. 1463–1470.
8.
Shanbhag
,
A. S.
,
Vai
,
C. W.
,
Qureshi
,
S. A.
, and
Rubsh
,
H. E.
, “
Characteristics of Cross-Linked UHMWPE Wear Debris
Proceedings 47th ORS Annual Meeting
,
2001
, p. 2.
9.
Scott
,
M.
,
Widding
,
K.
,
Ries
,
M.
, and
Shanbhag
,
A.
, “
Wear Particle Analyses of Conventional and Crosslinked UHMWPE Tested in an Anatomic Hip Simulator
”,
Proceedings 47th ORS Annual Meeting
,
2001
, p. 1.
10.
Sprecher
,
C.
,
Owen
,
G. R.
, and
Wimmer
,
M. A.
, “
Comparison of crosslinked and conventional polyethylene wear particles: A scanning electron microscopy study
”,
Proceedings European Society for Biomaterials Conference
,
2001
, p. 54.
11.
Endo
,
M. M.
,
Barbour
,
P. S.
,
Barton
,
D. C.
,
Fisher
,
J.
,
Tipper
,
J. L.
,
Ingham
,
E.
, and
Stone
,
M. H.
, “
Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene
”,
Bio-Medical Materials and Engineering
, Vol.
11
,
2001
, pp. 23–35.
12.
Endo
,
M. M.
,
Barbour
,
P. S.
,
Barton
,
D. C.
,
Wroblewski
,
B. M.
,
Fisher
,
J.
,
Tipper
,
J. L.
,
Ingham
,
E.
, and
Stone
,
M. H.
, “
A comparison of the wear and debris generation of GUR 1120 (compression moulded) and GUR 4150HP (ram extruded) ultra high molecular weight polyethylene
”,
Bio-Medical Materials and Engineering
, Vol.
9
,
1999
, pp.113–124.
13.
Landry
,
M. E.
,
Blanchard
,
C.
,
Mabrey
,
J. D.
, and
Agrawal
,
C. M.
, “
Wear Conditions Affecting Particle Size and Morphology
”,
Proceedings 43rd ORS Annual Meeting
,
1997
, p. 69.
14.
Landry
,
M. E.
,
Mabrey
,
J. D.
,
Blanchard
,
C.
, and
Agrawal
,
C. M.
, “
Effect of Wear Testing Parameters on UHMWPE Particle Morphology
”,
Proceedings 23rd Annual Meeting of the Society for Biomaterials
,
1997
, p. 193.
15.
Kobayashi
,
A.
,
Freeman
,
M. A.
,
Bonfield
,
W.
,
Kadoya
,
Y.
,
Yamac
,
T.
,
Al Saffar
,
N.
,
Scott
,
G.
, and
Revell
,
P.A.
, “
Number of polyethylene particles and osteolysis in total joint replacements. A quantitative study using a tissue-digestion method
,”
The Journal of Bone and Joint Surgery (British Vol.)
, Vol.
79
,
1997
, pp. 844–848.
16.
Howling
,
G. I.
,
Barnett
,
P. I.
,
Tipper
,
J. L.
,
Stone
,
M. H.
,
Fisher
,
J.
, and
Ingham
,
E.
, “
Quantitative characterization of polyethylene debris isolated from periprosthetic tissue in early failure knee implants and early and late failure Charnley hip implants
”,
Journal of Biomedical Materials Research
, Vol.
58
,
2001
, pp. 415–420.
17.
Schmalzried
,
T. P.
,
Campbell
,
P.
,
Schmitt
,
A. K.
, and
Brown
,
I. C.
,
Amstutz
,
H. C.
, “
Shapes and dimensional characteristics of polyethylene wear particles generated in vivo by total knee replacements compared to total hip replacements
”.
Journal of Biomedical Materials Research
, Vol.
38
,
1997
, pp. 203–210.
18.
Scott
,
M.
,
Wedding
,
K.
,
Ries
,
M.
and
Shanbhag
,
A
Wear Particle Analysis of Conventional and Crosslinked UHMWPE Tested in an Anatomic Hip Simulator
”, Proceedings 47th Orthopaedic Research Society,
2001
, p. 1.
19.
Scott
,
M.
,
Forster
,
H.
,
Vadodaria
,
K.
,
Sauer
,
W.
, and
Anthony
,
M.
, “
Validation of an Alternative Method for Isolating UHMWPE Wear Debris from Joint Simulator Serum
”, Proceedings 6th World Biomaterials Congress,
2000
, p. 177.
20.
Rastogi
,
S.
,
Kurelec
,
L.
, and
Lemstra
,
P. J.
, “
Chain Mobility in Polymer Systems: On the Borderline between Solid and Melt. 2. Crystal Size Influence in Phase Transition and Sintering of Ultrahigh Molecular Weight Polyethylene via the Mobile Hexagonal Phase
”,
Macromolecules
 0024-9297, Vol.
31
,
1998
, pp. 5022–5031.
21.
Wimmer
,
M. A.
,
Nassutt
,
R.
,
Lampe
,
F.
,
Schneider
,
E.
, and
Morlock
,
M. M.
, “
A new screening method designed for wear analysis of bearing surfaces used in total hip arthroplasty
”,
Alternative bearing surfaces in total joint replacement
, ASTM STP 1346,
Jacobs
J.J.
and
Craig
T. L.
, Eds.,
ASTM International
,
West Conshohocken, PA
,
1998
, pp. 30–43.
22.
Clarke
,
I. C
,
Johnson
,
S.
,
Phipatanakul
,
W.
, and
Good
,
V.
,
Effects of hip-loading input on simulated wear of A12O3-PTFE materials
,
Wear
 0043-1648, Vol.
250
,
2001
, pp. 159–166.
23.
Wimmer
,
M. A.
,
Kurelec
,
L.
,
Sprecher
,
C
,
Engel
,
K.
,
Hausam
,
V.
, and
Rastogi
,
S.
, “
Enhanced fusion of UHMWPE:. A concept to improve wear resistance and mechanical properties of polyethylene?
”, Proceedings 28th Annual Meeting Society for Biomaterials,
2002
, p. 536.
24.
Saikko
,
V.
,
Ahlroos
,
T.
, “
Wear simulation of UHMWPE for total hip replacement with a multidirectional motion pin-on-disk device: effects of counterface material, contact area, and lubricant
”,
Journal of Biomedical Materials Research
, Vol.
49
,
2000
, pp. 147–154.
This content is only available via PDF.
You do not currently have access to this chapter.
Close Modal

or Create an Account

Close Modal
Close Modal