Alternative Bearing Surfaces in Total Joint Replacement
By
JJ Jacobs
JJ Jacobs
Editor
Search for other works by this author on:
TL Craig
TL Craig
Editor
Search for other works by this author on:
ISBN-10:
0-8031-2490-2
ISBN:
978-0-8031-2490-5
No. of Pages:
277
Publisher:
ASTM International
Publication date:
1998

The alumina-on-alumina wear couple which was introduced about 20 years ago has received new attention because of its superior wear behavior. Improved material properties and new design concepts provide solutions which overcome the restrictions of the older cup design. The new design makes use of the beneficial properties of both ceramic and metal materials in a modular cup assembly. In this paper the material aspects are briefly reviewed first: the mechanical strength of medical grade alumina has been improved by about 40 % between 1978 and 1996. Results of finite element analysis of the stresses found in the ceramic cup insert are presented: it was found that the metal back cone angle has to be larger than the insert cone angle in order to minimize tensile stresses in the cup insert. In addition, stresses in the cup insert are minimized if the radial gap between cup insert and ball head is around 40 μm. The finite element results are confirmed by experimental findings on the resistance to static load and on fracture patterns. Also reported are results of cyclic fatigue experiments at up to 107 cycles which result in a fatigue limit of at least 19 kN. Preliminary results on the stability of the cup assembly under directionally oscillating loads show that there is no detectable motion between the cup insert and the metal back after a few load cycles.

1.
Richter
,
H.G.
;
Willmann
,
G.
, “
Reliability of Ceramic Components for Total Hip Endoprostheses
,”
Die Keramikpaarung BIOLOX in der Hüftendoprothetik (The Wear Couple BIOLOX for Hip Prostheses)
,
Puhl
W.
, Ed.,
Enke Vlg.
,
Stuttgart
,
1997
, pp77–83
2.
Willmann
,
G.
, “
Ceramic Components for Total Hip Arthroplasty
”,
Orthopedic Int.
5
(
1997
) 269–277
3.
Willmann
,
G.
, “
Ceramic cups for total hip replacement, part 3: Osseointegration of monolithic ceramic sockets
”,.
Biomedizinische Technik
42
(
1997
) 256.263
4.
Blömer
,
W.
,
Design Aspects of Modular Inlay Fixation
, “
Performance of the Wear Couple BIOLOX forte in hip arthroplasty
. Proceedings of the 2nd Symposium on Ceramic Wear Couple,
Puhl
W.
, Ed.
Enke
,
Stuttgart
,
1997
5.
Dalla Pria
,
P.
, “
Recent Innovations Relating to the Use of Ceramic-Ceramic Hip Joint Prostheses
”,
Puhl
W.
, Ed. “
Die Keramikpaarung BIOLOX in der Hüftendoprothetik
,
Enke
,
Stuttgart
,
1996
6.
Richter
,
H.G.
,
Willmann
,
G.
,
Wimmer
,
M.
and
Osthues
,
F.G.
, “
Influence of the Ball/Stem-Interface on the load bearing capability of modular total hip endoprostheses
”,
Modularity of Orthopedic Implants
, ASTM STP 1301,
Parr
Jack E.
,
Mayor
Michael B.
, and
Marlowe
Donald E.
, Eds.,
American Society for Testing and Materials
,
Philadelphia
,
1996
7.
Bachnik
,
M.
,
Hasenpusch
,
M.
, et al
, “
The Effect of Hardness and Surfece Quality of Metal Tapers on the Fracture Load of Ceramic Ball Heads in Hip Endoprostheses
”,
Biomedizinische Technik
Vol
39
, No.
12
,
1994
, pp 302–306.
This content is only available via PDF.
You do not currently have access to this chapter.
Close Modal

or Create an Account

Close Modal
Close Modal