Skip to Main Content
Skip Nav Destination
ASTM Selected Technical Papers
Environmental Toxicology and Risk Assessment: Seventh Volume
By
EE Little
EE Little
1
Symposium chairman and co-editor
; U.S. Geological Survey/Biological Resources Division
Environmental and Contaminants Research Center
?
Columbia, MO
.
Search for other works by this author on:
BM Greenberg
BM Greenberg
2
Symposium co-chairman and co-editor
; Department of Biology
University of Waterloo
?
Waterloo, Ontario,
Canada
Search for other works by this author on:
AJ DeLonay
AJ DeLonay
3
Symposium co-chairman and co-editor
; U.S. Geological Survey/Biological Resources Division
Environmental and Contaminants Research Center
?
Columbia, MO
.
Search for other works by this author on:
ISBN-10:
0-8031-2479-1
ISBN:
978-0-8031-2479-0
No. of Pages:
427
Publisher:
ASTM International
Publication date:
1998

Semipermeable membrane devices (SPMDs) were used to monitor polycyclic aromatic hydrocarbons (PAHs) in an urban stream. Replicate SPMDs were exposed during seven consecutive 14-day periods and analyzed for PAHs. Relative percent differences (RPDs) were calculated to determine precision (reproducibility) in SPMD replicates. RPDs ranged from 13.9% to 56.0% (n=14). Variations in replicates encompassed SPMD preparation, deployment, exposure, retrieval, and analysis. Seven SPMDs were spiked at various intervals throughout the study with a mixture of all PAH analytes at 2.0 μg/g triolein per compound. Average percent recovery (n=7) varied from 52% to 82%. Method detection limits (MDLs) were also assessed by spiking ten SPMDs at 0.200 μg/g with equal amounts of a PAH mixture. Most MDLs for PAHs in SPMDs ranged from 0.054 to 0.178 μg/g triolein, however, if considering a 14-day exposure period, these MDLs can be translated into water concentrations of 2.1 ng/L to 13 ng/L. These values are as much as 2 000 times lower than MDLs for methods which employ solvent extraction and high performance liquid chromatography to directly measure PAHs in water. Blank SPMDs were prepared, and analyzed along with each set of field exposures and proved to be free of PAH contaminants above MDLs.

1.
Code of Federal Regulations
.
Protection of Environment
,
U.S. Government Printing Office
, Parts 100 to 149,
1986
.
2.
Crunkilton
,
R. L.
and
DeVita
,
W. M.
, “
Determination of aqueous concentrations of polycyclic aromatic hydrocarbons (PAHs) in an urban stream
,”
Chemosphere
 0045-6535. Vol.
35
,
1997
, pp. 1447–1464.
3.
Gustafson
,
K. E.
and
Dickhut
R. M.
, “
Distribution of polycyclic aromatic hydrocarbons in southern Chesapeake Bay surface water: evaluation of three methods for determination of freely dissolved water concentrations
,”
Environmental Toxicology and Chemistry
. Vol.
16
,
1997
, pp. 452–461.
4.
Huckins
,
J. N.
,
Tubergen
,
M. W.
, and
Manuweera
,
G. W.
, “
Semipermeable membrane devices containing model lipid: A new approach to monitoring the bioavailibility of lipophilic contaminants and estimating their bioconcentration potential
,”
Chemosphere
 0045-6535, Vol.
20
, No.
5
,
1990
, pp. 533–552.
5.
Huckins
,
J. N.
,
Manuweera
,
G. K.
,
Petty
,
J. D.
,
Mackay
,
D.
and
Lebo
,
J. A.
, “
Lipid-containing semipermeable devices for monitoring organic contaminants in water
”,
Environmental Science and Technology
 0013-936X Vol.
27
, 1993, pp. 2489–2496.
6.
Lebo
,
J. A.
,
Zajicek
,
J. L.
,
Orazio
,
C. E.
,
Petty
,
J. D.
and
Huckins
J. N.
, “
Use of the semipermeable device to sample aromatic hydrocarbons pollution in a lotic system.
Polycyclic Aromatic Compounds
, Vol.
8
,
1996
, pp. 53–65.
7.
Petty
,
J. D.
,
Huckins
,
J. N.
and
Zajicek
,
J. L.
, “
Application of semipermeable membrane devices as passive air samplers
,”
Chemosphere
 0045-6535, Vol.
27
,
1993
, pp. 1609–1624.
8.
Petty
,
J. D.
,
Huckins
,
J. N.
,
Orazio
,
C. E.
,
Lebo
,
J. A.
,
Clark
,
R. C.
and
Gibson
V. L.
, “
Laboratory studies of the use of semipermeable membrane devices (SPMDs) as passive water samplers of polyaromatic hydrocarbon (PAH) priority pollutants
”, National Biological Service,
Midwest Science Center
, A report to the American Petroleum Institute, Amoco Oil Co. and Chevron Oil Co.,
1995
.
9.
Manuweera
,
G. K.
, “
Kinetic and thermodynamic studies of permeation of non-polar organic contaminants through polyethylene
,” Ph.D. dissertation,
University of Missouri
, Columbia, MO.,
1992
, 148 pp.
10.
Standard Methods for the Analysis of Water and Wastewater
, 19th edition,
American Public Health Association
,
Washington, D.C.
,
1995
.
This content is only available via PDF.
You do not currently have access to this chapter.
Close Modal

or Create an Account

Close Modal
Close Modal