Skip to Main Content
Skip Nav Destination
ASTM Selected Technical Papers
Dredging, Remediation, and Containment of Contaminated Sediments
By
KR Demars
KR Demars
editor
Search for other works by this author on:
GN Richardson
GN Richardson
editor
Search for other works by this author on:
RN Yong
RN Yong
editor
Search for other works by this author on:
RC Chaney
RC Chaney
editor
Search for other works by this author on:
ISBN-10:
0-8031-2028-1
ISBN:
978-0-8031-2028-0
No. of Pages:
343
Publisher:
ASTM International
Publication date:
1995

Soil-bentonite slurry cutoff walls (SBSCWs) have been used for decades by geotechnical engineers in conjunction with soil excavation to control ground water movement. In recent years, soil-bentonite slurry cutoff walls have been increasingly used as containment barriers around contaminated soils to impede or, in some cases, nearly eliminate the off-site migration of contaminated ground water or other potentially hazardous liquids. Because of this recent application, the conventional design methodologies for the soil-bentonite slurry cutoff walls, specifically the requirements for the soil-bentonite slurry mix acceptance, have been adjusted. Low hydraulic conductivity, workability, and physical stability commonly used as the main acceptance criteria for conventional soil-bentonite slurry mixes are no longer the only governing parameters. Compatibility of the soil-bentonite slurry mix with the ground water/liquid is as important and should be considered a major factor in the soil-bentonite slurry mix design.

The paper presents the procedures used and the results obtained during an extensive laboratory testing program performed to select varying soil-bentonite slurry mix components for a soil-bentonite slurry cutoff wall constructed around an old landfill at a former oil refinery. The landfill is underlain to varying depths by a coarse granular soil that has been exposed to oil-products. Compatibility of three commercially available bentonite products with the free oil products and the oil-contaminated ground water found at some locations in the landfill was initially investigated. Based on the test results, one of the bentonite products was selected for use in the soil-bentonite slurry testing program. A clayey soil from a borrow source, potable water from the site, and subsurface soils from the proposed soil-bentonite slurry wall alignment were used to form different soil-bentonite slurry mixes. Slump tests were performed to evaluate the workability of the mixes. Based on the test results, a single mix was selected for further study, including permeability/compatibility testing. The results of the compatibility testing program are presented and discussed in the paper. A specific design mix methodology for evaluating the chemical compatibility of soil-bentonite slurry mixes with permeants is proposed.

1.
Case International Company
,
1982
,
Case Slurry Wall Notebook
,
Manufacturers' Data, Case International
,
Houston, TX
.
2.
D'Appolonia
,
D. J.
,
1980
, “
Soil-Bentonite Slurry Trench Cutoffs
,”
Journal of the Geotechnical Engineering Division of ASCE
 0093-6405, Vol.
106
, No.
4
, pp. 399–417.
3.
Spooner
,
P.
,
Wetzel
,
R.
,
Spooner
,
C.
, et al
,
1985
,
Slurry Trench Construction for Pollution Migration Control
,
Noyes Publication
,
Park Ridge, NJ
.
4.
Xanthakos
,
P. P.
,
1979
,
Slurry Walls
,
McGraw-Hill Book Company
,
New York
.
This content is only available via PDF.
You do not currently have access to this chapter.
Close Modal

or Create an Account

Close Modal
Close Modal