Commercially pure titanium is standardized by ISO 5832-2 and has better fatigue strength than stainless steel. Its other mechanical properties are comparable to the properties of stainless steel.

Bone plates need contouring in most cases of application. A retrospective evaluation of more than 500 clinical cases showed that the initiated strain by contouring is on average about 1.6% below the elongation at fracture for cp titanium. Therefore, contouring of titanium plates having equivalent design to stainless steel plates is not critical.

The most important properties of pure titanium are its excellent biocompatibility and its corrosion resistance. The metal is protected by a very thin and tough layer of titanium oxide. Anodizing gives the titanium oxide layer a certain color.

No allergic reactions to cp titanium are known so far. The debris of titanium caused by relative movement of implant parts which are in contact consists of titanium oxide and has a dark color. This may be sometimes undesirable for cosmetic reasons but the particles do not contain any toxic element.

Pure Titanium is an appropriate material for bone plates and screws used for internal fixation.

1.
Lane
,
W.A.
:
The operative treatment of fractures
,
London
,
The Medical Publishing C.
,
1914
2.
Lambotte
,
A.
:
Les débits de L'osteosynthése en Belgique
. Ed. Société Belge de chirurgie orthoped. et de Traumotologie 1921 1971, Bruxelles,
1971
3.
Beder
,
O.E.
;
Eade
,
G.
:
An investigation of tissue tolerance to titanium metal implants in dogs
.
Surgery
39
, p. 470–473,
1956
.
4.
Frankle
,
M.A.
;
Cordey
,
J.
;
Frankle
,
M.D.
;
Baumgart
,
F.
;
Perren
,
S.M.
:
A Retrospective Analysis of Plate Contouring in the Tibia using the conventional 4.5mm (narrow) DC Plate
,
J. of Orthop.Trauma
, submitted
1991
, to be published in
1993
.
5.
Steinemann
,
S.G.
;
Mäusli
,
P.-A.
;
Szmukler-Moncler
,
S.
;
Semlitsch
,
M.
;
Pohler
,
O.
;
Hintermann
,
H.-E.
;
Perren
,
S.M.
:
Beta-Titanium Alloy for Surgical Implants
, paper presented at the Seventh World Conference on Titanium,
06
1992
,
San Diego
6.
Perren
,
S.
 et al
: Biomaterials conf.,
Paris
,
1987
.
7.
ISO 5832-2 Implants for Surgery — Metallic Materials — Part II: Unalloyed Titanium
,
International Organization for Standardization
,
Geneva, Switzerland
8.
Rüedi
,
Th.P.
:
Titan und Stahl in der Knochenchirurgie, Hefte zur Unfallheilkunde
, Heft 123,
Springer-Verlag
,
Berlin Heidelberg New York
,
1975
9.
ISO 5832-3 Implants for Surgery — Metallic Materials — Part 3: Wrought titanium 6 aluminum 4 vanadium alloy
,
International Organization for Standardization
,
Geneva, Switzerland
10.
ISO DIS 5832-11 Implants for Surgery — Metallic Materials — Part 11: Titanium 6 aluminum 7 niobium alloy, Draft International Standard 1993
,
International Organization for Standardization
,
Geneva, Switzerland
11.
ISO 5832-10 Implants for Surgery — Metallic Materials — Part 10: Titanium 5 aluminum 2.5 ironalloy
,
International Organization for Standardization
,
Geneva, Switzerland
12.
Frey
,
N.
;
Buchillier
,
T.
;
Le
,
V.-D.
;
Steinemann
,
S.G.
:
Properties of surface oxides on titanium and some titanium alloys
, paper presented at the Seventh World Conference on Titanium,
06
1992
,
San Diego
13.
Gerber
,
H.
;
Perren
,
S.
: “
Evaluation of Tissue Compatibility of in vitro Cultures of Embryonic Bone
”, in Evaluation of Biomaterials,
John Wiley & Sons Ltd.
,
1980
, pp. 307–314
14.
Hierholzer
,
S.
and G.:
Osteosynthese und Metallallergie — Klinische Untersuchungen, Immunologie und Histologie des Implantatlagers
, in: Traumatologie aktuell,
Georg Thieme Verlag Stuttgart
,
New York
1991
15.
Steinemann
,
S.G.
: Personal communication,
1992
.
16.
Matter
,
P.
 et al
in:
AO/ASIF Poster exhibition at SICOT
1990
, Montreal, Canada.
17.
Matter
 et al
:
Annual meeting of the Swiss Society of Surgery
,
Davos
,
1993
18.
Allgöwer
,
M.
;
Müller
,
M.E.
;
Schneider
,
R
;
Willenegger
,
H.
:
Manual of internal fixation
, third edition,
Springer
,
1991
This content is only available via PDF.
You do not currently have access to this chapter.
Close Modal

or Create an Account

Close Modal
Close Modal