Skip Nav Destination
100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959 : ASTM International, 1990.
ASTM Selected Technical Papers
Air Change Rate and Airtightness in BuildingsAvailable to Purchase
By
MH Sherman
MH Sherman
1
Lawrence Berkeley Laboratory, University of California
, Berkeley, CA, 94720
; editor and symposium chairman
Search for other works by this author on:
ISBN-10:
0-8031-1451-6
ISBN:
978-0-8031-1451-7
No. of Pages:
317
Publisher:
ASTM International
Publication date:
1990
Description
Information on state-of-the-art techniques for measuring air change rates. Many papers contain measured data on either airtightness or air change rates, some from large datasets. Papers also address the error associated with making field measurement using various techniques. 22 peer-reviewed papers appear in sections on tracer gas techniques, air exchange rate measurement, residential airtightness, multizone leakage, and comparison of techniques. For blower door contractors, researchers, specification writers, government agencies.
Sherman, M.
Air Change Rate and Airtightness in Buildings. ISBN-10: 0-8031-1451-6
ISBN: 978-0-8031-1451-7
No. of Pages: 317
ISBN (electronic): 978-0-8031-5128-4
Publisher: ASTM International
Published: 1990
Download citation file:
Table of Contents
-
OverviewByMH ShermanMH Sherman1Lawrence Berkeley Laboratory, University of California,Berkeley, CA, 94720;editor and symposium chairmanSearch for other works by this author on:
-
Tracer Gas Measurement Systems Compared in a Multifamily BuildingByDT Harrje,DT Harrje1Princeton University,Princeton, NJ 08544.Search for other works by this author on:RN Dietz,RN Dietz2Brookhaven National Laboratory,Upton, NY 11973.Search for other works by this author on:M Sherman,M Sherman3Lawrence Berkeley Laboratory,Berkeley, CA 94720.Search for other works by this author on:DL Bohac,DL Bohac3Lawrence Berkeley Laboratory,Berkeley, CA 94720.Search for other works by this author on:TW D'Ottavio,TW D'Ottavio2Brookhaven National Laboratory,Upton, NY 11973.Search for other works by this author on:DJ DickerhoffDJ Dickerhoff3Lawrence Berkeley Laboratory,Berkeley, CA 94720.Search for other works by this author on:
-
A Numerical Investigation of the Constant Tracer Flow Technique
-
Measuring Airflow Rates with Pulse Tracer TechniquesByAK Persily,AK Persily1Mechanical engineer,National Institute of Standards and Technology,Gaithersburg, MD 20899.Search for other works by this author on:J AxleyJ Axley2Department of Architecture,Massachusetts Institute of Technology,Cambridge, MA 02139.Search for other works by this author on:
-
Air Change Measurements of Five Army Buildings in AlaskaBySN FlandersSN Flanders1Research civil engineer,U.S. Army Cold Regions Research and Engineering Laboratory,Hanover, NH 03755-1290.Search for other works by this author on:
-
The User's Influence on Air ChangeByPF ColletPF Collet2Technological Institute,Taastrup,.DenmarkSearch for other works by this author on:
-
The Relation of CO2 Concentration to Office Building VentilationByA Persily,A Persily1Mechanical engineer,National Institute of Standards and Technology,Gaithersburg, MD 20899.Search for other works by this author on:WS DolsWS Dols1Mechanical engineer,National Institute of Standards and Technology,Gaithersburg, MD 20899.Search for other works by this author on:
-
The Northwest Residential Infiltration Survey: A Field Study of Ventilation in New Homes in the Pacific NorthwestByGB Parker,GB Parker1Senior research engineer,Battelle—Pacific NW Laboratories, P.O. Box 999,Richland, WA 99352.Search for other works by this author on:M McSorley,M McSorley2Residential programs manager,Washington State Energy Office,Olympia, WA 98504.Search for other works by this author on:J HarrisJ Harris3Conservation programs analyst,Northwest Power Planning Council,Portland, OR 97205.Search for other works by this author on:
-
Comparison of Methods for the Measurement of Air Change Rates and Interzonal Airflows in Two Test ResidencesByRC Fortmann,RC Fortmann1Assistant director, Indoor Environment Division;director, Indoor Environment Division; andresearch scientist, respectively,GEOMET Technologies, Inc.,20251 Century Blvd., Germantown, MD 20874-1192.Search for other works by this author on:NL Nagda,NL Nagda1Assistant director, Indoor Environment Division;director, Indoor Environment Division; andresearch scientist, respectively,GEOMET Technologies, Inc.,20251 Century Blvd., Germantown, MD 20874-1192.Search for other works by this author on:HE RectorHE Rector1Assistant director, Indoor Environment Division;director, Indoor Environment Division; andresearch scientist, respectively,GEOMET Technologies, Inc.,20251 Century Blvd., Germantown, MD 20874-1192.Search for other works by this author on:
-
Results of a Pre-Field Measurement Program Fan Pressurization Comparative TestByDL HadleyDL Hadley1Senior research scientist,Battelle, Pacific Northwest Laboratory,Richland, WA 99352.Search for other works by this author on:
-
The Effects of Wind on Residential Building Leakage Measurements
-
Fan Door Testing on Crawl Space BuildingsByT Brennan,T Brennan1Camroden Associates, RD #4, Box 62,Rome, NY 13440.Search for other works by this author on:B Pyle,B Pyle2Southern Research Institute, Box 55305,Birmingham, AL 35255.Search for other works by this author on:A Williamson,A Williamson2Southern Research Institute, Box 55305,Birmingham, AL 35255.Search for other works by this author on:F Balzer,F Balzer2Southern Research Institute, Box 55305,Birmingham, AL 35255.Search for other works by this author on:M OsborneM Osborne3USEPA, Air and Energy Engineering Research Lab,Research Triangle Park, NC 27711.Search for other works by this author on:
-
Air Leakage Tests of Manufactured Housing in the Northwest United StatesByCW Ek,CW Ek1Test engineer,Bonneville Power Administration,Vancouver, WA 98666.Search for other works by this author on:SA Onisko,SA Onisko2Manufactured housing program manager,Bonneville Power Administration,Portland, OR 97208.Search for other works by this author on:GO GreggGO Gregg3Owner,George O. Gregg Co.,Bainbridge Island, WA 98110.Search for other works by this author on:
-
Air Leakage Measurements in Dwellings in TurkeyByAH Tanribilir,AH Tanribilir1Building Research Institute (YAE), Scientific and Technical Research Council of Turkey (TUBITAK),Ankara,.TurkeySearch for other works by this author on:R Oskay,R Oskay2Department of Mechanical Engineering,Middle East Technical University (ODTÜ),Ankara,.TurkeySearch for other works by this author on:C YenerC Yener1Building Research Institute (YAE), Scientific and Technical Research Council of Turkey (TUBITAK),Ankara,.TurkeySearch for other works by this author on:
-
Investigation of a Fan-Pressurization Technique for Measuring Interzonal Air LeakageByMP Modera,MP Modera1Staff scientist and guest researcher, respectively, Applied Science Division,Lawrence Berkeley Laboratory,Berkeley, Ca 94720. (Mr. Herrlin is employed by the Division of Building Services Engineering,Royal Institute of Technology,S-100044 Stockholm,.SwedenSearch for other works by this author on:MK HerrlinMK Herrlin1Staff scientist and guest researcher, respectively, Applied Science Division,Lawrence Berkeley Laboratory,Berkeley, Ca 94720. (Mr. Herrlin is employed by the Division of Building Services Engineering,Royal Institute of Technology,S-100044 Stockholm,.SwedenSearch for other works by this author on:
-
Airtightness Survey of Row Houses in Calgary, AlbertaByJA LoveJA Love1Associate professor, Faculty of Environmental Design,The University of Calgary,Calgary, Alberta,.CanadaSearch for other works by this author on:
-
Airtightness Measurements in Two UK Office BuildingsByMDAES Perera,MDAES Perera1Head, Non-Domestic Ventilation Section, Environmental Systems Division,Building Research Establishment (BRE),Garston,.UKSearch for other works by this author on:RK Stephen,RK Stephen2Member, Domestic Ventilation Section, Environmental Physics Division,BRE,Garston,.UKSearch for other works by this author on:RG TullRG Tull3Member, Non-Domestic Ventilation Section, Environmental Systems Division,BRE,Garston,.UKSearch for other works by this author on:
-
Methods for Measuring Air Leakage in High-Rise ApartmentsByC-Y Shaw,C-Y Shaw1Research officer,Institute for Research in Construction, National Research Council,.CanadaSearch for other works by this author on:S Gasparetto,S Gasparetto2Industrial development officer,Ministry of Energy,Province of Ontario,.CanadaSearch for other works by this author on:JT ReardonJT Reardon1Research officer,Institute for Research in Construction, National Research Council,.CanadaSearch for other works by this author on:
-
Simple Test Method for Evaluating Exterior Wall Airtightness of Tall Office BuildingsByS Hayakawa,S Hayakawa1Chief research engineer and senior research engineer, respectively, Building Environmental Engineering Department,Kajima Institute of Construction Technology,Tokyo 182,.JapanSearch for other works by this author on:S TogariS Togari1Chief research engineer and senior research engineer, respectively, Building Environmental Engineering Department,Kajima Institute of Construction Technology,Tokyo 182,.JapanSearch for other works by this author on:
-
Measurement of Airtightness, Air Infiltration, and Indoor Air Quality in Ten Detached Houses in Sendai, JapanByH Yoshino,H Yoshino1Associate professor, professor, and graduate student, respectively, Department of Architecture, Faculty of Engineering,Tohoku University,Sendai, 980,.JapanSearch for other works by this author on:M Nagatomo,M Nagatomo1Associate professor, professor, and graduate student, respectively, Department of Architecture, Faculty of Engineering,Tohoku University,Sendai, 980,.JapanSearch for other works by this author on:Y Yamamoto,Y Yamamoto1Associate professor, professor, and graduate student, respectively, Department of Architecture, Faculty of Engineering,Tohoku University,Sendai, 980,.JapanSearch for other works by this author on:H Matsumoto,H Matsumoto2Lecturer, Department of Regional Planning,Toyohashi University of Technology,Toyohashi, 440,.JapanSearch for other works by this author on:Y UtsumiY Utsumi3Associate researcher, Department of Architecture,Miyagi National College of Technology,Sendai, 980,.JapanSearch for other works by this author on:
-
Comparison of Different Methods for Airtightness and Air Change Rate DeterminationByMB NantkaMB Nantka1Doctor of Science,Silesian Technical University,Gliwice,.PolandSearch for other works by this author on:
-
Airtightness Characteristics of Electrically Heated Houses in the Residential Standards Demonstration ProgramByDS ParkerDS Parker1Research analyst,Florida Solar Energy Center,300 State Road 401, Cape Canaveral, FL 32920.Search for other works by this author on:
-
Air Infiltration and Ventilation Centre's Guide to Air Exchange Rate and Airtightness Measurement TechniquesByPS CharlesworthPS Charlesworth1Senior scientist, Air Infiltration and Ventilation Centre,University of Warwick Science Park,Coventry,.UKSearch for other works by this author on:
Email alerts
Copyright
All rights reserved. This material may not be reproduced or copied, in whole or in part, in any printed, mechanical, electronic, film, or other distribution and storage media, without the written consent of the publisher.
© 1990
ASTM International