Skip to Main Content
Skip Nav Destination
ASTM Selected Technical Papers
Consolidation of Soils: Testing and Evaluation
By
RN Yong
RN Yong
1
Geotechnical Research Centre, McGill University
,
Montreal,
Canada
, H3A 2K6
;
symposium co-chairman and co-editor
Search for other works by this author on:
FC Townsend
FC Townsend
2Department of Civil Engineering,
University of Florida
,
Gainesville, Fla. 32611
;
symposium co-chairman and co-editor
Search for other works by this author on:
ISBN-10:
0-8031-0446-4
ISBN:
978-0-8031-0446-4
No. of Pages:
760
Publisher:
ASTM International
Publication date:
1986

The determination of clay suspension concentration can be done either by nondestructive or by destructive techniques. Non-destructive techniques such as transmission by radiation and total pressure measurement devices are either expensive or have a limited range of application, whereas destructive tests such as ovendrying require a large amount of sample, whch can limit both the number of sampling ports and the frequency of sampling.

An apparatus has been developed which permits us to draw small-size specimens (less than 0.5 mL volume) from the settling columns, simultaneously from various depths, while at the same time causing minimum disturbance to the sample in the sedimentation column.

The determination of solids concentration in the small size specimen drawn from the sedimentation column is by “fall-drop” technique, whereby a drop of known volume (20 μL) is allowed to fall through a column of immiscible organic liquid. From the velocity of the falling drop the concentration of the suspension can be computed using a calibration curve. Various organic liquids with different densities at room temperature have been tested. The requirements for the selection of these liquids include: reasonable price, low melting point, high boiling point, low vapor pressure, nontoxicity, Newtonian, and immiscible with water, and no chemical reaction with salt solutions. The variations in density and viscosity of these liquids with temperature are presented in this paper. Based on this information, the proper choice of the organic liquid required for measuring the anticipated concentration of the suspension can be made so that the time measured for the fall of a drop between two points (400 mm apart) is sufficiently large (>30 s) and laminar flow prevails for the liquid through which the drop falls.

1.
Coe
,
H. S.
and
Clevenger
,
G. H.
,
Transactions
, American Institute of Mining Engineers, Vol.
55
, No.
9
,
1916
, pp. 356-384.
2.
Kynch
,
C. J.
,
Transactions
, Faraday Society, Vol.
48
,
1952
, pp. 166-176.
3.
Vesilind
,
P. A.
,
Treatment and Disposal of Wastewater Sludges
,
Ann Arbor Science
,
Ann Arbor, MI
,
1979
, p. 110.
4.
Gibson
,
R. E.
,
Schiffman
,
R. L.
, and
Cargill
,
K. W.
,
Canadian Geotechnical Journal
 0008-3674, Vol.
18
,
1981
, pp. 280-293.
5.
Michaels
,
A. S.
and
Bolger
,
J. C.
,
Industrial and Engineering Chemistry Fundamentals
, Vol.
1
, No.
1
,
02
1962
, pp. 24-33.
6.
Richardson
,
J. F.
,
Transactions
, Institute of Chemical Engineers, Vol.
38
,
1960
, pp. 33-42.
7.
Andreasen
,
A. H. M.
,
Kolloid-Zeitschrift
 0368-6590, Vol.
49
,
1929
, pp. 253-265.
8.
Yong
,
R. N.
and
Sethi
,
A. J.
,
Journal of Canadian Petroleum Technology
 0021-9487, Vol.
17
,
1978
, pp. 76-83.
9.
Morgenstern
,
N.
and
Amir-Tahmasseb
,
I.
,
Geotechnique
 0016-8505, Vol.
15
,
1965
, pp. 387-395.
10.
Tiller
,
F. M.
and
Khatib
,
Z.
,
Journal of Colloid and Interface Science
 0021-9797, Vol.
100
,
1984
, pp. 55-67.
This content is only available via PDF.
You do not currently have access to this chapter.
Close Modal

or Create an Account

Close Modal
Close Modal