Skip Nav Destination
100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959 : ASTM International, 1985.
ASTM Selected Technical Papers
Guarded Hot Plate and Heat Flow Meter Methodology
By
CJ Shirtliffe,
CJ Shirtliffe
1Division of Building Research, ;
National Research Council
, Canada
K1A 0R6editor
.
Search for other works by this author on:
RP Tye
RP Tye
2Thermatest Department,
Dynatech R/D Company
, Cambridge, MA 02139
; editor
.
Search for other works by this author on:
ISBN-10:
0-8031-0423-5
ISBN:
978-0-8031-0423-5
No. of Pages:
252
Publisher:
ASTM International
Publication date:
1985
Description
This book discusses improvements, problems, and issues that affect reliable thermal measurements by the guarded hot plate and heat flow meter methods. It examines current apparatus design, operation and use; precision and accuracy; analysis and error. It reveals that progress is being made in the effort to make more accurate, reproducible measurements at all temperature.
Shirtliffe, C, & Tye, R.
Guarded Hot Plate and Heat Flow Meter Methodology. ISBN-10: 0-8031-0423-5
ISBN: 978-0-8031-0423-5
No. of Pages: 252
ISBN (electronic): 978-0-8031-4944-1
Publisher: ASTM International
Published: 1985
Download citation file:
Table of Contents
-
IntroductionByCJ Shirtliffe,CJ Shirtliffe1Division of Building Research,National Research Council,;CanadaK1A 0R6editor.Search for other works by this author on:RP TyeRP Tye2Thermatest Department,Dynatech R/D Company,Cambridge, MA 02139;editor.Search for other works by this author on:
-
Analysis of Errors in Guarded Hot Plate Measurements as Compiled by the Finite Element MethodByLR TroussartLR Troussart1Director of Manufacturing and Process Development,Pittsburgh Corning Europe N. V.,B-3980 Tessenderlo,.BelgiumSearch for other works by this author on:
-
Thermal Conductivity Measurements with the Plate Apparatus: Influence of the Guard Ring Width on the Accuracy of MeasurementsByK-H BodeK-H Bode1Physikalisch-Technische Bundesanstalt,Bundesallee 100, D-3300 Braunschweig,.West GermanySearch for other works by this author on:
-
Error Analysis of Measuring Thermal Conductivity by Circular and One Side Heat Flow Type Guarded Hot Plate ApparatusByK EguchiK Eguchi1Principal research director,Building Research Institute, Ministry of Construction,Tsukuba,.JapanSearch for other works by this author on:
-
Summary of Error Analysis for the National Bureau of Standards 1016-mm Guarded Hot Plate and Considerations Regarding Systematic Error for the Heat Flow Meter ApparatusByB RennexB Rennex1Physicist,National Bureau of Standards,Washington, DC 20234.Search for other works by this author on:
-
Evaluation of Thermal Conductance of Liquefied Natural Gas Tank InsulationByE BrendengE Brendeng1Professor, Division of Refrigeration Engineering,The Norwegian Institute of Technology,Trondheim,.NorwaySearch for other works by this author on:
-
Present and Future Research on Guarded Hot Plate and Heat Flow Meter ApparatusByF De PonteF De Ponte1Professor,University of Padova, Istituto di Fisica Tecnica,Padova,.ItalySearch for other works by this author on:
-
A Flat Insulation Tester That Uses an Unguarded Nichrome Screen Wire HeaterByDL McElroy,DL McElroy1Group leader, senior technologist, adjunct research, participant, and research staff member,Martin Marietta Energy Systems, Inc.,Oak Ridge, TN 37830.Search for other works by this author on:RS Graves,RS Graves1Group leader, senior technologist, adjunct research, participant, and research staff member,Martin Marietta Energy Systems, Inc.,Oak Ridge, TN 37830.Search for other works by this author on:DW Yarbrough,DW Yarbrough1Group leader, senior technologist, adjunct research, participant, and research staff member,Martin Marietta Energy Systems, Inc.,Oak Ridge, TN 37830.Search for other works by this author on:JP MooreJP Moore1Group leader, senior technologist, adjunct research, participant, and research staff member,Martin Marietta Energy Systems, Inc.,Oak Ridge, TN 37830.Search for other works by this author on:
-
Discussion of Heat Flow Meter Apparatus and Transfer Standards Used for Error AnalysisByM Bomberg,M Bomberg1Senior research officers, Division of Building Research,National Research Council of Canada,Ottawa,.CanadaSearch for other works by this author on:KR SolvasonKR Solvason1Senior research officers, Division of Building Research,National Research Council of Canada,Ottawa,.CanadaSearch for other works by this author on:
-
Use of a Heat Flow Meter Apparatus for Testing Loose-Fill Materials Prepared for Laboratory TestingByDJ McCaaDJ McCaa1Supervisor,Thermal Testing Laboratory, Certain Teed Corporation,Blue Bell, PA 19422.Search for other works by this author on:
-
A Review of Current Commercially Available Guarded Hot Plate and Heat Flow Meter Apparatus and InstrumentationByKG CoumouKG Coumou1Vice President,Dynatech R/D Company,Cambridge, MA 02139.Search for other works by this author on:
-
Development of a Large Area Heat Flow MeterByY Miyake,Y Miyake1Products and technical director,EKO Instruments Trading Co., Ltd.,21-8 Hatagaya 1-chome, Shibuya-ku, Tokyo 151,.JapanSearch for other works by this author on:K EguchiK Eguchi2Principal research director,Building Research Institute, Ministry of Construction,Tachihara-1, Oho-machi, Tsukuba-gun, Ibaragi-Pref.,.JapanSearch for other works by this author on:
-
Recent Developments with the Thin-Heater Thermal Conductivity ApparatusByNE Hager, JrNE Hager, Jr1Senior research associate,Research and Development, Armstrong World Industries, Inc.,Lancaster, PA 17604.Search for other works by this author on:
-
Development of a Company Wide Heat Flow Meter Calibration Program Based on the National Bureau of Standards Certified Transfer SpecimensByCM PelanneCM Pelanne14900 Pinyon Drive, Littleton, CO 80123.Search for other works by this author on:
-
Field Measurements of Steady-State Thermal Transfer Properties of Insulation SystemsByDC LarsonDC Larson1Professor of Physics and Atmospheric Science,Center for Insulation Technology, Drexel University,Philadelphia, PA 19104.Search for other works by this author on:
-
Surface Temperature Sensor Calibration: In Situ TechniqueBySP SchumannSP Schumann1Engineer,Technical Center, Owens Corning Fiberglas,Granville, OH 43023.Search for other works by this author on:
-
SummaryByCJ Shirtliffe,CJ Shirtliffe1Division of Building Research,National Research Council,Canada K1A 0R6;editor.Search for other works by this author on:RP TyeRP Tye2Thermatest Department,Dynatech R/D Company,Cambridge, MA 02139;editor.Search for other works by this author on:
Email alerts
Copyright
All rights reserved. This material may not be reproduced or copied, in whole or in part, in any printed, mechanical, electronic, film, or other distribution and storage media, without the written consent of the publisher.
© 1985
ASTM International