Skip Nav Destination
ASTM Selected Technical Papers
Building Air Change Rate and Infiltration Measurements
By
HR Trechsel
HR Trechsel
1
National Bureau of Standards
, Washington, D.C. 20234
; symposium chairman
.
Search for other works by this author on:
ISBN-10:
0-8031-0607-6
ISBN:
978-0-8031-0607-9
No. of Pages:
195
Publisher:
ASTM International
Publication date:
1980
eBook Chapter
An Automated Controlled-Flow Air Infiltration Measurement System
By
PE Condon
,
PE Condon
1
Lawrence Berkeley Laboratories, University of California
, Berkeley, Calif. 94720
.
Search for other works by this author on:
DT Grimsrud
,
DT Grimsrud
1
Lawrence Berkeley Laboratories, University of California
, Berkeley, Calif. 94720
.
Search for other works by this author on:
MH Sherman
,
MH Sherman
1
Lawrence Berkeley Laboratories, University of California
, Berkeley, Calif. 94720
.
Search for other works by this author on:
RC Kammerud
RC Kammerud
1
Lawrence Berkeley Laboratories, University of California
, Berkeley, Calif. 94720
.
Search for other works by this author on:
Page Count:
13
-
Published:1980
Citation
Condon, P, Grimsrud, D, Sherman, M, & Kammerud, R. "An Automated Controlled-Flow Air Infiltration Measurement System." Building Air Change Rate and Infiltration Measurements. Ed. Trechsel, H. 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959 : ASTM International, 1980.
Download citation file:
A description is presented of an automated, controlled flow air infiltration measurement system. This system measures total air flow, a volume per unit time, due to infiltration in a test space. Data analysis is discussed and the mixing problem is analyzed. Different modes of operating the system are considered: (a) concentration decay, (b) continuous flow in a single chamber, and (c) continuous flow in a multichamber enclosure. Problems associated with the use of nitrous oxide as a tracer gas are described.
References
1.
Dick
, J. B.
, Heating, Piping, and Air Conditioning
, Vol. 22
, 1950
, pp. 131-137.2.
Hitchen
, E. R.
and Wilson
, C. B.
, Building Science
0007-3628, Vol. 2
, 1967
, pp. 59-82.3.
Honma
, Hiroshi
, Ventilation of Buildings and Its Disturbances
, Faibo Grafiska
, Stockholm
, 1975
.4.
Harrje
, D. T.
and Grot
, R.
, Proceedings
, International Conference on Energy Use Management
, Pergamon Press
, New York
, 1977
, pp. 457-464.5.
Sinden
, F. W.
, “Theoretical Basis for Tracer Gas Measurements of Air Infiltration
,” Note 5
, Princeton University, Center for Environmental Studies
, 03
1976
.6.
Grimsrud
, D. T.
, Sherman
, M. H.
, Diamond
, R. C.
, Condon
, P. E.
, and Rosenfeld
, A. H.
, Transactions
, American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Vol. 85
, 1979
, Lawrence Berkeley Laboratory Report
LBL-7824, Berkeley, Calif.7.
Bruce
, D. L.
and Bach
, M. J.
, “Trace Effects of Anesthetic Gases on Behavioral Performance of Operating Room Personnel
, HEW Publication No. (NIOSH) 76–169, U.S. Department of Health, Education and Welfare, Public Health Service, Center for Disease Control, National Institute for Occupational Safety and Health
, Cincinnati
, 1976
.8.
“
Occupational Exposure to Waste Anesthetic Gases and Vapors
,” HEW Publication No. (NIOSH) 77–140, Superintendent of Documents, U.S. Government Printing Office
, Washington, D.C.
, 1977
.
This content is only available via PDF.
You do not currently have access to this chapter.
Email alerts
Related Chapters
Residential Air Pollution Levels: Observation and Data Interpretation
Building Air Change Rate and Infiltration Measurements
Infrasonic Measurement of Building Air Leakage: A Progress Report
Building Air Change Rate and Infiltration Measurements
Natural and Mechanical Ventilation in Tight Swedish Homes—Measurements and Modelling
Measured Air Leakage of Buildings
Air Infiltration Reduction Through Retrofitting
Building Air Change Rate and Infiltration Measurements
Related Articles
What are the Required Conditions for Heavy Structure Buildings to be Thermally Effective in a Hot Humid Climate?
J. Sol. Energy Eng (August,2004)
Displacement of Natural Ventilation in an Enclosure With a Convective/Radiative Heat Source and Nonadiabatic Envelopes
J. Sol. Energy Eng (February,2006)
Evaluation of a High-Performance Solar Home in Loveland, Colorado
J. Sol. Energy Eng (May,2007)