Restraint in Fire Tests of Concrete Floors and Roofs
By
S. L. Selvaggio
,
S. L. Selvaggio
1
Senior research engineer
, Fire Research Section, Portland Cement Assn.
, Skokie, Ill
.
Search for other works by this author on:
C. C. Carlson
C. C. Carlson
2
Consultant
, Department of Technical Information, Manager of Fire Research Section
, Portland Cement Assn.
, Skokie, Ill
. Personal member ASTM
.
Search for other works by this author on:
Page Count:
19
-
Published:1967
Citation
Selvaggio, SL, & Carlson, CC. "Restraint in Fire Tests of Concrete Floors and Roofs." Symposium on Fire Test Methods—Restraint & Smoke 1966. Ed. Committee E-5, . 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959 : ASTM International, 1967.
Download citation file:
In standard fire tests of floor and roof constructions for buildings, restraint of thermal expansion is commonly simulated in the laboratory by enclosing the specimen within a rigid restraining frame. Restraining capability and restraint intensity applied to similar test specimens varies among different laboratories. Factors affecting restraint of thermal expansion of floor and roof constructions in building fires are discussed. The conditions contributing to maximum restraint are presented, and a rational approach is given for its uniform simulation in laboratory fire tests. Other conditions of restraint of thermal expansion are discussed.
Keywords:
fire tests,
concrete,
floors,
roofs,
building construction,
restraint,
columns,
thermal expansion
References
1.
Philleo
, Robert
, “Some Physical Properties of Concrete at High Temperatures
,” Proceedings, American Concrete Institute
, Vol 54
, 04
1958
, p. 857.2.
Selvaggio
, S. L.
and Carlson
, C. C.
, “Effect of Restraint on Fire Resistance of Prestressed Concrete
,” Fire Test Methods
, ASTM STP No. 344, American Society for Testing and Materials
, 1962
.3.
Shideler
, J. J.
, “Lightweight Aggregate Concrete for Structural Use
,” Proceedings, American Concrete Institute
, Vol 54
, 10
1957
, p. 299.4.
Fruchtbaum
, J.
, “Fire Damage to General Mills Building and Its Repair
,” Proceedings, American Concrete Institute
, Vol 37
, 01
1941
.5.
Report of Committee on Edison Fire
, Proceedings, American Concrete Institute
, Vol 3
, 02
1915
.6.
Timoshenko
, S.
, “Strength of Materials, Part II, Advanced Theory and Problems
,” 3rd ed., Van Nostrand
, New York
, 1956
.7.
Issen
, Lionel
, et al, “Fire Tests of Concrete Members: Influence of Aggregate and Reinforcement on Thermal Restraint Forces
,” in preparation.8.
Cruz
, C. R.
, “Elastic Properties of Concrete at High Temperatures
,” Journal, PCA Research and Development Laboratories
, Vol 8
, No. 1
, 01
1966
, pp. 37–45.9.
Carlson
, C. C.
, et al, “A Review of Studies of the Effects of Restraint on the Fire Resistance of Prestressed Concrete
,” Proceedings, Symposium on Fire Resistance of Prestressed Concrete
, Braunschweig, Germany
, 1965
, International Federation for Prestressing (F.I.P.). Bauverlag GmbH
, Wiesbaden, Germany
. Reprinted as PCA Research Department Bulletin 206.10.
Ehm
, H.
and vonPostel
, R.
, “Tests of Continuous Reinforced Beams and Slabs Under Fire
,” Proceedings, Symposium on Fire Resistance of Prestressed Concrete
, Translation available at “S.L.A. Translation Center,” John Crerar Library
, Chicago, Ill
.11.
Report No. BI-59-22, “
Fire Test of a Simple, Statically Indeterminant Beam
,” TNO Institute for Structural Materials and Building Structures
, Delft, Holland. Translation available at “S.L.A. Translation Center,” John Crerar Library, Chicago, Ill.12.
U. L. Report File R 4123-5-7-8, “
Report on Floor and Roof Construction Consisting of Prestressed Concrete Single Tee Slabs
,” Prestressed Concrete Institute
, Chicago, Ill.13.
Selvaggio
, S. L.
and Carlson
, C. C.
, “Fire Resistance of Prestressed Concrete Beams, Study B-Influence of Aggregate and Load Intensity
,” Journal, PCA Research and Development Laboratories
, Vol 6
, No. 1
, 01
1964
.
This content is only available via PDF.
You do not currently have access to this chapter.
Email alerts
Related Chapters
Temperature Criteria at Failure
Fire Test Performance
Deflection and Failure of Steel-Supported Floors and Beams in Fire
Symposium on Fire Test Methods—Restraint & Smoke 1966
New Criteria for Fire Endurance Tests
Fire Test Performance
Load and Fire Test Data on Steel-Supported Floor Assemblies
Symposium on Fire Test Methods—Restraint & Smoke 1966
Related Articles
A Critical Review of Construction Using 3D Printing Technology
J. Eng. Sustain. Bldgs. Cities (May,2023)
Elliptical Deformation of a Floating Roof Pontoon Due to Radial Second Mode of Sloshing (Effect of the Geometry of Pontoon Cross-Section on the Hoop Membrane Stress)
J. Pressure Vessel Technol (October,2011)
Vibration Analysis of a Floating Roof Taking Into Account the Nonlinearity of Sloshing
J. Appl. Mech (July,2008)