MiTiHeart™ LVAD is a rotary centrifugal blood pump with a hybrid passive/active magnetic bearing support system. It exhibits low power loss, low vibration, and high reliability under transient operating conditions. Unique features of the design include a simple and direct flow path for both main and washing blood flows, non-contact pump rotor, i.e., no rubbing surfaces, and relatively large clearances between the pump rotor and housing. The first prototype was constructed from medical grade polycarbonate. To reduce the possibility of thrombosis, the internally exposed surfaces were coated with a biocompatible polymer. Hemolysis test results showed a low normalized index of hemolysis of 0.01 mg/dL. An acute animal test was successfully completed at the Hershey Medical Center. During the test, the pump was implanted in a calf and operated in parallel with the heart. Following the acute test a chronic 200-hour implant study was completed. A second prototype was constructed using a titanium alloy for all blood contacting surfaces and incorporating a redundant hydrodynamic thrust bearing. This prototype was successfully evaluated in two chronic implant studies in a calf animal model for a total of 130 hours.
Skip Nav Destination
World Tribology Congress III
September 12–16, 2005
Washington, D.C., USA
Conference Sponsors:
- Tribology Division
ISBN:
0-7918-4202-9
PROCEEDINGS PAPER
Magnetically Suspended Rotary Blood Pump (Keynote)
Hooshang Heshmat,
Hooshang Heshmat
Mohawk Innovative Technology, Inc., Albany, NY
Search for other works by this author on:
James F. Walton, II,
James F. Walton, II
Mohawk Innovative Technology, Inc., Albany, NY
Search for other works by this author on:
Michael J. Tomaszewski,
Michael J. Tomaszewski
Mohawk Innovative Technology, Inc., Albany, NY
Search for other works by this author on:
Said Jahanmir
Said Jahanmir
MiTiHeart Corporation, Gaithersburg, MD
Search for other works by this author on:
Hooshang Heshmat
Mohawk Innovative Technology, Inc., Albany, NY
James F. Walton, II
Mohawk Innovative Technology, Inc., Albany, NY
Michael J. Tomaszewski
Mohawk Innovative Technology, Inc., Albany, NY
Said Jahanmir
MiTiHeart Corporation, Gaithersburg, MD
Paper No:
WTC2005-63681, pp. 611-612; 2 pages
Published Online:
November 17, 2008
Citation
Heshmat, H, Walton, JF, II, Tomaszewski, MJ, & Jahanmir, S. "Magnetically Suspended Rotary Blood Pump (Keynote)." Proceedings of the World Tribology Congress III. World Tribology Congress III, Volume 2. Washington, D.C., USA. September 12–16, 2005. pp. 611-612. ASME. https://doi.org/10.1115/WTC2005-63681
Download citation file:
10
Views
Related Proceedings Papers
Related Articles
Magnetic Thrust Bearing Operation and Industrial Pump Application
J. Eng. Gas Turbines Power (January,1997)
Measured Force/Current Relations in Solid Magnetic Thrust Bearings
J. Eng. Gas Turbines Power (January,1997)
Related Chapters
Introduction
Design of Mechanical Bearings in Cardiac Assist Devices
Conclusion
Magnetic Bearings for Mechanical Cardiac Assist Devices
Generating Synthetic Electrocardiogram Signals Withcontrolled Temporal and Spectral Characteristics
Intelligent Engineering Systems through Artificial Neural Networks Volume 18