Tip leakage flow induces high heat transfer to the blade tip and causes significant aerodynamic losses. In this paper, we propose a multi-cavity squealer tip with an additional rib in the squealer cavity. Our study investigated the effects of the rib location and shape on the blade tip heat transfer and the total pressure loss. Experiments were performed in a five-bladed linear cascade using a low speed wind tunnel. The blade chord, pitch, and span length were 126mm, 102.7mm, and 160mm, respectively. The Reynolds number, based on the blade chord and cascade exit velocity, was 2.44×105, and a tip clearance of 1.25% of the blade span was considered. The additional rib was installed in the squealer tip cavity near the leading edge, the mid-chord, and the training edge, respectively. The shape of the rib was also varied from rectangular to triangular in order to minimize the rib surface area exposed to the hot gas. The secondary flow and total pressure loss were measured using a seven-hole probe at one-chord downstream of the blade trailing edge, and the heat transfer coefficient distributions were measured by utilizing the hue-detection based transient liquid crystal technique. Flow measurement results indicated that the proposed multi-cavity tip reduced the total pressure loss. The blade tip heat transfer measurement results showed that the proposed multi-cavity tip was able to reduce the maximum heat transfer region near the cavity floor near the leading edge, but the heat transfer on the second cavity floor increased due to the leakage flow reattachment.
Skip Nav Destination
ASME 2013 Turbine Blade Tip Symposium
September 30–October 3, 2013
Hamburg, Germany
Conference Sponsors:
- International Gas Turbine Institute
ISBN:
978-0-7918-5607-9
PROCEEDINGS PAPER
Measurement of Blade Tip Heat Transfer and Leakage Flow in a Turbine Cascade With a Multi-Cavity Squealer Tip
Jung Shin Park,
Jung Shin Park
Korea Aerospace University, Goyang, Gyeonggi, Korea
Search for other works by this author on:
Sang Hoon Lee,
Sang Hoon Lee
Korea Aerospace University, Goyang, Gyeonggi, Korea
Search for other works by this author on:
Jae Su Kwak,
Jae Su Kwak
Korea Aerospace University, Goyang, Gyeonggi, Korea
Search for other works by this author on:
Jin Taek Chung
Jin Taek Chung
Korea University, Seoul, Korea
Search for other works by this author on:
Jung Shin Park
Korea Aerospace University, Goyang, Gyeonggi, Korea
Sang Hoon Lee
Korea Aerospace University, Goyang, Gyeonggi, Korea
Jae Su Kwak
Korea Aerospace University, Goyang, Gyeonggi, Korea
Won Suk Lee
Korea University, Seoul, Korea
Jin Taek Chung
Korea University, Seoul, Korea
Paper No:
TBTS2013-2072, V001T02A006; 9 pages
Published Online:
February 20, 2014
Citation
Park, JS, Lee, SH, Kwak, JS, Lee, WS, & Chung, JT. "Measurement of Blade Tip Heat Transfer and Leakage Flow in a Turbine Cascade With a Multi-Cavity Squealer Tip." Proceedings of the ASME 2013 Turbine Blade Tip Symposium. ASME 2013 Turbine Blade Tip Symposium. Hamburg, Germany. September 30–October 3, 2013. V001T02A006. ASME. https://doi.org/10.1115/TBTS2013-2072
Download citation file:
101
Views
Related Proceedings Papers
Related Articles
Effect of Squealer Geometry Arrangement on a Gas Turbine Blade Tip
Heat Transfer
J. Heat Transfer (June,2002)
Aerothermal Investigations of Tip Leakage Flow in Axial Flow Turbines—Part II: Effect of Relative Casing Motion
J. Turbomach (January,2009)
Related Chapters
Dynamic Behavior of Pumping Systems
Pipeline Pumping and Compression Systems: A Practical Approach
Pulsation and Vibration Analysis of Compression and Pumping Systems
Pipeline Pumping and Compression Systems: A Practical Approach, Second Edition
Pulsation and Vibration Analysis of Compression and Pumping Systems
Pipeline Pumping and Compression System: A Practical Approach, Third Edition