Clinical assessment of fracture healing is usually subjective, relying upon the detection of movement (‘feel’) by the surgeon, the patient’s response in terms of pain and confidence, and radiographic evidence of callus and primary bone union. A more quantitative, objective method of measuring the strength of a healing callus would be useful in assessing many aspects, such as the effectiveness of different forms of treatment, the pattern and rate of healing, and the stage at which the patient can return to full weight-bearing activity. The results presented in this paper demonstrate the complexity of monitoring fracture healing in leg stance phase using an instrumented intramedullary (IM) nail equipped with a single sensor. The bone healers exhibited both sigmoidal and linear load responses during fracture healing. Ambulating non-healers demonstrated high nail forces which did not change significantly over time whereas lame non-healers demonstrated a decreasing nail load due to reduced GRF or loosening of fixation.
Skip Nav Destination
ASME 2008 Conference on Smart Materials, Adaptive Structures and Intelligent Systems
October 28–30, 2008
Ellicott City, Maryland, USA
Conference Sponsors:
- Aerospace Division
ISBN:
978-0-7918-4332-1
PROCEEDINGS PAPER
Structural Health Monitoring of Long Bone Fractures Using Instrumented Intramedullary Nails
Darren Wilson,
Darren Wilson
Smith & Nephew, UK Ltd., Heslington, York, Yorkshire, UK
Search for other works by this author on:
Si Janna
Si Janna
Smith and Nephew, Inc, Memphis, TN
Search for other works by this author on:
Darren Wilson
Smith & Nephew, UK Ltd., Heslington, York, Yorkshire, UK
Si Janna
Smith and Nephew, Inc, Memphis, TN
Paper No:
SMASIS2008-314, pp. 1-3; 3 pages
Published Online:
July 13, 2009
Citation
Wilson, D, & Janna, S. "Structural Health Monitoring of Long Bone Fractures Using Instrumented Intramedullary Nails." Proceedings of the ASME 2008 Conference on Smart Materials, Adaptive Structures and Intelligent Systems. Smart Materials, Adaptive Structures and Intelligent Systems, Volume 2. Ellicott City, Maryland, USA. October 28–30, 2008. pp. 1-3. ASME. https://doi.org/10.1115/SMASIS2008-314
Download citation file:
15
Views
Related Proceedings Papers
Related Articles
The Effects of Dynamic Loading on Bone Fracture Healing Under Ilizarov Circular Fixators
J Biomech Eng (May,2019)
Finite Element Prediction of Proximal Femoral Fracture Patterns Under Different Loads
J Biomech Eng (February,2005)
An Effective Approach for Optimization of a Composite Intramedullary Nail for Treating Femoral Shaft Fractures
J Biomech Eng (December,2015)
Related Chapters
Introduction
Computer Vision for Structural Dynamics and Health Monitoring
Achievements, Challenges, and Opportunities
Computer Vision for Structural Dynamics and Health Monitoring
Introduction and Definitions
Handbook on Stiffness & Damping in Mechanical Design