The long-term fixation characteristics of stent grafts used to treat aortic aneurysms are likely related to the nature of its apposition to the aortic wall after deployment. But we only have a rudimentary understanding of the mechanisms involved and the factors that determine the nature of deployment of these implants. One factor that has been shown to be of particular relevance is oversizing — the % difference between the size of the graft to that of the aorta in which it is deployed (oversizing implies the former is larger) [1]. Other proposed factors include the angulation in the aortic neck and stent design. Naturally, issues of mechanics are central to this problem. Computational models of the mechanics involved, if developed with rigor, can be useful for gaining insights into the mechanisms involved and for interrogating the interactions among these multiple factors.
Skip Nav Destination
ASME 2012 Summer Bioengineering Conference
June 20–23, 2012
Fajardo, Puerto Rico, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-4480-9
PROCEEDINGS PAPER
Radial Compressive Properties of an Aortic Stent Graft
Chaid Schwarz,
Chaid Schwarz
University of Iowa, Iowa City, IA
Search for other works by this author on:
Madhavan L. Raghavan
Madhavan L. Raghavan
University of Iowa, Iowa City, IA
Search for other works by this author on:
Chaid Schwarz
University of Iowa, Iowa City, IA
Madhavan L. Raghavan
University of Iowa, Iowa City, IA
Paper No:
SBC2012-80889, pp. 877-878; 2 pages
Published Online:
July 19, 2013
Citation
Schwarz, C, & Raghavan, ML. "Radial Compressive Properties of an Aortic Stent Graft." Proceedings of the ASME 2012 Summer Bioengineering Conference. ASME 2012 Summer Bioengineering Conference, Parts A and B. Fajardo, Puerto Rico, USA. June 20–23, 2012. pp. 877-878. ASME. https://doi.org/10.1115/SBC2012-80889
Download citation file:
5
Views
Related Proceedings Papers
Related Articles
A Wireless, Passive Sensor for Monitoring the Pressure of an Abdominal Aortic Aneurysm Sac
J. Med. Devices (June,2008)
Two-Dimensional Optimization of a Stent for an Aneurysm
J. Med. Devices (June,2010)
Impact of Stents and Flow Diverters on Hemodynamics in Idealized Aneurysm Models
J Biomech Eng (July,2011)
Related Chapters
mDFA Human Empirical Results
Modified Detrended Fluctuation Analysis (mDFA)
In-Vitro Modeling of the Dynamic Forces in the Femoropopliteal Artery
Fatigue and Fracture of Medical Metallic Materials and Devices: 2nd Volume
The Quest for Fatigue-Resistant Nitinol for Medical Implants
Fourth Symposium on Fatigue and Fracture of Metallic Medical Materials and Devices