Cardiac output (CO) monitoring is essential for the optimal management of critically ill patients. Several methods have been proposed for CO estimation based on arterial pressure waveform analysis, known as “pulse contour cardiac output” (PCCO) monitoring. Most of them are based on invasive recording of blood pressure and require repeated calibrations, while they are still subject to inaccuracy under specific conditions. The Systolic Volume Balance (SVB) method was developed as a new non-invasive method based on physical principles and was further validated by a one-dimensional model of the systemic arterial tree. CO estimates were compared against the “real” CO values of the one dimensional model. 507 different hemodynamic cases were simulated by altering heart rate (HR), total arterial compliance (C) and total arterial resistance (R). It was found that CO can be accurately estimated by the new SVB formula. The bias between the brachial PCCO and the model’s CO was 0.042 L/min with 0.341 L/min SD of difference. The limits of agreement were −0.7–0.6 L/min indicating high precision. The intraclass correlation coefficient and the root mean square error between estimated and “real” CO values were 0.861 and 0.041 L/min respectively, indicating good accuracy and agreement.
Skip Nav Destination
ASME 2012 Summer Bioengineering Conference
June 20–23, 2012
Fajardo, Puerto Rico, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-4480-9
PROCEEDINGS PAPER
A New Pulse Contour Analysis for Cardiac Output Estimation: The Systolic Volume Balance Method
Orestis Vardoulis,
Orestis Vardoulis
Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
Search for other works by this author on:
Theodore G. Papaioannou,
Theodore G. Papaioannou
Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
Search for other works by this author on:
Nikos Stergiopulos
Nikos Stergiopulos
Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
Search for other works by this author on:
Orestis Vardoulis
Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
Theodore G. Papaioannou
Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
Nikos Stergiopulos
Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
Paper No:
SBC2012-80167, pp. 73-74; 2 pages
Published Online:
July 19, 2013
Citation
Vardoulis, O, Papaioannou, TG, & Stergiopulos, N. "A New Pulse Contour Analysis for Cardiac Output Estimation: The Systolic Volume Balance Method." Proceedings of the ASME 2012 Summer Bioengineering Conference. ASME 2012 Summer Bioengineering Conference, Parts A and B. Fajardo, Puerto Rico, USA. June 20–23, 2012. pp. 73-74. ASME. https://doi.org/10.1115/SBC2012-80167
Download citation file:
6
Views
Related Proceedings Papers
Related Articles
Autonomous Calibration of Hexapod Machine Tools
J. Manuf. Sci. Eng (February,2000)
Influence of Geometric Parameters on the Hemodynamic Characteristics of the Vertebral Artery
J Biomech Eng (March,2025)
Computational Study of Hemodynamic Effects of Abnormal E / A Ratio on Left Ventricular Filling
J Biomech Eng (June,2014)
Related Chapters
Analysis the Effect of IMU Calibration Errors on SINS/GPS Integration Accuracy for Airborne Earth Observation
International Symposium on Information Engineering and Electronic Commerce, 3rd (IEEC 2011)
4-Bit Pipeline ADC for Monolithic Active Pixel Sensors
International Conference on Advanced Computer Theory and Engineering (ICACTE 2009)
Mechanical Measurements and Calibration
Metrology and Instrumentation: Practical Applications for Engineering and Manufacturing