Heart disease affects millions of people each year. However, only a limited number of people benefit from a heart transplant due to the scarce supply of donor hearts. Ventricular assist devices (VADs) provide an alternative way to augment or replace the function of one or more chambers of a failing heart. Fluid dynamics in these devices plays a key role in their function and blood biocompatibility. Although current devices are more biocompatible than their forerunners, they still cause blood damage, such as hemolysis, platelet activation, thrombosis and embolization, which may result in serious clinical events and are directly related to fluid dynamics and artificial materials of these devices. Significant research efforts have been devoted to studying the device-blood interactions and minimizing these non-physiological fluid dynamic conditions to improve the functional characteristics and bio/hemo-compatibility of these medical devices.
Skip Nav Destination
ASME 2012 Summer Bioengineering Conference
June 20–23, 2012
Fajardo, Puerto Rico, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-4480-9
PROCEEDINGS PAPER
Experimental Validation of Fluid Dynamic Numerical Models in Blood Pump Simulation Available to Purchase
Jiafeng Zhang,
Jiafeng Zhang
University of Maryland School of Medicine, Baltimore, MD
Search for other works by this author on:
Pei Zhang,
Pei Zhang
University of Maryland School of Medicine, Baltimore, MD
Search for other works by this author on:
Kate Fraser,
Kate Fraser
University of Maryland School of Medicine, Baltimore, MD
Search for other works by this author on:
Bartley P. Griffith,
Bartley P. Griffith
University of Maryland School of Medicine, Baltimore, MD
Search for other works by this author on:
Zhongjun J. Wu
Zhongjun J. Wu
University of Maryland School of Medicine, Baltimore, MD
Search for other works by this author on:
Jiafeng Zhang
University of Maryland School of Medicine, Baltimore, MD
Pei Zhang
University of Maryland School of Medicine, Baltimore, MD
Kate Fraser
University of Maryland School of Medicine, Baltimore, MD
Bartley P. Griffith
University of Maryland School of Medicine, Baltimore, MD
Zhongjun J. Wu
University of Maryland School of Medicine, Baltimore, MD
Paper No:
SBC2012-80855, pp. 575-576; 2 pages
Published Online:
July 19, 2013
Citation
Zhang, J, Zhang, P, Fraser, K, Griffith, BP, & Wu, ZJ. "Experimental Validation of Fluid Dynamic Numerical Models in Blood Pump Simulation." Proceedings of the ASME 2012 Summer Bioengineering Conference. ASME 2012 Summer Bioengineering Conference, Parts A and B. Fajardo, Puerto Rico, USA. June 20–23, 2012. pp. 575-576. ASME. https://doi.org/10.1115/SBC2012-80855
Download citation file:
13
Views
Related Proceedings Papers
Related Articles
Ventricular Assist Devices: Current State and Challenges
J. Med. Devices (December,2017)
A Quantitative Comparison of Mechanical Blood Damage Parameters in Rotary Ventricular Assist Devices: Shear Stress, Exposure Time and Hemolysis Index
J Biomech Eng (August,2012)
Numerical Study of Shear-Induced Thrombus Formation Over Aterial Stent Struts
J. Med. Devices (June,2009)
Related Chapters
Introduction
Mechanical Blood Trauma in Circulatory-Assist Devices
Introduction
Design of Mechanical Bearings in Cardiac Assist Devices
Role of Artificial Intelligence in Hepatitis B Diagnosis
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3