Researchers have sought to explain the development and progression of knee osteoarthritis using in vivo estimates of knee contact forces. Unfortunately, it is not possible to measure knee contact forces in a clinical environment. Thus, studies often estimate knee contact forces using a variety of external measures. For example, inverse dynamics knee loads such as the adduction moment and superior force are frequently used as surrogate measures of medial and total knee contact force, respectively. Contraction of muscles spanning the knee is believed to increase knee contact force, and hence muscle electromyographic (EMG) signals are another external measure that may be indicative of internal contact force. The recent development of instrumented knee implants, such as the eTibia design [1], has provided access to in vivo knee contact force data during gait and other activities. However, few studies have correlated inverse dynamics loads, and none have correlated EMG signals, with total, medial, and lateral in vivo knee contact forces.
Skip Nav Destination
ASME 2012 Summer Bioengineering Conference
June 20–23, 2012
Fajardo, Puerto Rico, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-4480-9
PROCEEDINGS PAPER
Correlation Between In Vivo Knee Contact Forces and External Measures During Gait
Andrew J. Meyer,
Andrew J. Meyer
University of Florida, Gainesville, FL
Search for other works by this author on:
Darryl D. D’Lima,
Darryl D. D’Lima
Shiley Center for Orthopaedic Research & Education, Scripps Clinic, La Jolla, CA
Search for other works by this author on:
Scott A. Banks,
Scott A. Banks
University of Florida, Gainesville, FL
Search for other works by this author on:
David G. Lloyd,
David G. Lloyd
Griffith University, Griffith Health Institute, QLD, Australia
Search for other works by this author on:
Thor F. Besier,
Thor F. Besier
University of Auckland, Auckland Bioengineering Institute, Auckland, New Zealand
Search for other works by this author on:
Clifford W. Colwell,
Clifford W. Colwell
Shiley Center for Orthopaedic Research & Education, Scripps Clinic, La Jolla, CA
Search for other works by this author on:
Benjamin J. Fregly
Benjamin J. Fregly
University of Florida, Gainesville, FL
Search for other works by this author on:
Andrew J. Meyer
University of Florida, Gainesville, FL
Darryl D. D’Lima
Shiley Center for Orthopaedic Research & Education, Scripps Clinic, La Jolla, CA
Scott A. Banks
University of Florida, Gainesville, FL
David G. Lloyd
Griffith University, Griffith Health Institute, QLD, Australia
Thor F. Besier
University of Auckland, Auckland Bioengineering Institute, Auckland, New Zealand
Clifford W. Colwell
Shiley Center for Orthopaedic Research & Education, Scripps Clinic, La Jolla, CA
Benjamin J. Fregly
University of Florida, Gainesville, FL
Paper No:
SBC2012-80918, pp. 369-370; 2 pages
Published Online:
July 19, 2013
Citation
Meyer, AJ, D’Lima, DD, Banks, SA, Lloyd, DG, Besier, TF, Colwell, CW, & Fregly, BJ. "Correlation Between In Vivo Knee Contact Forces and External Measures During Gait." Proceedings of the ASME 2012 Summer Bioengineering Conference. ASME 2012 Summer Bioengineering Conference, Parts A and B. Fajardo, Puerto Rico, USA. June 20–23, 2012. pp. 369-370. ASME. https://doi.org/10.1115/SBC2012-80918
Download citation file:
9
Views
Related Proceedings Papers
Related Articles
The Therapress 1600i: Accelerating Knee Rehabilitation
J. Med. Devices (June,2009)
Multibody Muscle Driven Model of an Instrumented Prosthetic Knee During Squat and Toe Rise Motions
J Biomech Eng (April,2013)
Related Chapters
Classification of Electromyogram Signal for Control of Robotic Gripper
International Conference on Computer Engineering and Technology, 3rd (ICCET 2011)
Modeling and Classification for Uterine EMG Signals Using Autoregressive Model
Intelligent Engineering Systems through Artificial Neural Networks, Volume 16
Generating Synthetic Electrocardiogram Signals Withcontrolled Temporal and Spectral Characteristics
Intelligent Engineering Systems through Artificial Neural Networks Volume 18