Motor vehicle collisions (MVCs) commonly result in serious blunt abdominal injuries [1]. Although abdominal injuries account for only 3–5% of all injuries observed in MVCs, they comprise 8% of AIS 3+ injuries, 16.5% of AIS 4+ injuries and 20.5% of AIS 5+ injuries [24]. Currently, no crash test dummies used to assess injury risk in MVCs are equipped to represent individual solid abdominal organs located asymmetrically in the human abdomen. Consequently, researchers and safety engineers rely on finite element models (FEMs) to assess the risk of automotive related abdominal injuries. However, the response of these models must be locally and globally validated based on appropriate biomechanical data in order to accurately assess injury risk. There have only been a few studies which have investigated the compressive material properties of liver or spleen by performing compression tests on isolated samples [5–8]. Although these studies have provided considerable insight into the factors that affect the material response of the liver and spleen parenchyma, these studies have been limited to testing of animal tissue, sub-failure loading, or a single loading rate. Therefore, the purpose of this study was to quantify the compressive material properties of human liver and spleen parenchyma at various loading rates in order to characterize the viscoelastic and failure response.
Skip Nav Destination
ASME 2012 Summer Bioengineering Conference
June 20–23, 2012
Fajardo, Puerto Rico, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-4480-9
PROCEEDINGS PAPER
Biomechanical Response of Human Liver and Spleen Parenchyma in Uniaxial Unconfined Compression
Andrew R. Kemper,
Andrew R. Kemper
Virginia Tech-Wake Forest University, Blacksburg, VA
Search for other works by this author on:
Anthony C. Santago,
Anthony C. Santago
Virginia Tech-Wake Forest University, Winston-Salem, NC
Search for other works by this author on:
Joel D. Stitzel,
Joel D. Stitzel
Virginia Tech-Wake Forest University, Blacksburg, VA
Search for other works by this author on:
Jessica L. Sparks,
Jessica L. Sparks
Virginia Tech-Wake Forest University, Winston-Salem, NC
Search for other works by this author on:
Stefan M. Duma
Stefan M. Duma
Virginia Tech-Wake Forest University, Blacksburg, VA
Search for other works by this author on:
Andrew R. Kemper
Virginia Tech-Wake Forest University, Blacksburg, VA
Anthony C. Santago
Virginia Tech-Wake Forest University, Winston-Salem, NC
Joel D. Stitzel
Virginia Tech-Wake Forest University, Blacksburg, VA
Jessica L. Sparks
Virginia Tech-Wake Forest University, Winston-Salem, NC
Stefan M. Duma
Virginia Tech-Wake Forest University, Blacksburg, VA
Paper No:
SBC2012-80895, pp. 285-286; 2 pages
Published Online:
July 19, 2013
Citation
Kemper, AR, Santago, AC, Stitzel, JD, Sparks, JL, & Duma, SM. "Biomechanical Response of Human Liver and Spleen Parenchyma in Uniaxial Unconfined Compression." Proceedings of the ASME 2012 Summer Bioengineering Conference. ASME 2012 Summer Bioengineering Conference, Parts A and B. Fajardo, Puerto Rico, USA. June 20–23, 2012. pp. 285-286. ASME. https://doi.org/10.1115/SBC2012-80895
Download citation file:
12
Views
Related Proceedings Papers
Related Articles
Effect of Strain Rate on the Material Properties of Human Liver Parenchyma in Unconfined Compression
J Biomech Eng (October,2013)
The Nonlinear Material Properties of Liver Tissue Determined From No-Slip Uniaxial Compression Experiments
J Biomech Eng (June,2007)
Effect of Strain Rate on the Tensile Material Properties of Human Placenta
J Biomech Eng (September,2009)
Related Chapters
USE OF A GEOHAZARD MANAGEMENT PROGRAM TO REDUCE PIPELINE FAILURE RATES
Pipeline Integrity Management Under Geohazard Conditions (PIMG)
Load Transfer in Single Rivet-Row Lap Joints (Conventional and Countersunk)
Structural Shear Joints: Analyses, Properties and Design for Repeat Loading
Compilation of Results for Open Hole Panels and Butt Joints
Structural Shear Joints: Analyses, Properties and Design for Repeat Loading