The airflow perturbation device (APD) has been developed as a portable, easy to use, and rapid-response instrument for noninvasively measuring respiratory resistance in humans. However, the APD has limited data validating it against established techniques; moreover, a method does not exist to standardize resistance measurement outputs between APD units. This study proposes a system that simulates the normal range of human breathing to validate the APD with the clinically accepted impulse oscillometry technique. Two respiratory resistance ranges were tested. The validation system consisted of a sinusoidal flow generator with ten standardized resistance configurations that were shown to represent a total range of resistances from 0.7000–9.4475 cmH2O·L−1·s−1. Impulse oscillometry (IOS) measurements and APD measurements of the calibration system were recorded and compared at a constant volumetric flow rate of 0.150 L·s−1. Both IOS and the APD consistently failed to estimate nominal resistance accurately. However, a strong second-order relationship was observed between APD measurements and IOS measurements (R2 = 0.997). Because of their comparability to IOS measurements, APD measurements are shown to be valid representations of respiratory resistance in a standard pneumatic model.
Skip Nav Destination
ASME 2011 Summer Bioengineering Conference
June 22–25, 2011
Farmington, Pennsylvania, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-5458-7
PROCEEDINGS PAPER
Validation of Respiratory Resistance Measurements Available to Purchase
James Pan,
James Pan
University of Maryland, College Park, MD
Search for other works by this author on:
Andrew Saltos,
Andrew Saltos
University of Maryland School of Medicine, Baltimore, MD
Search for other works by this author on:
Dan Smith,
Dan Smith
University of Maryland School of Medicine, Baltimore, MD
Search for other works by this author on:
Arthur Johnson,
Arthur Johnson
University of Maryland, College Park, MD
Search for other works by this author on:
Jafar Vossoughi
Jafar Vossoughi
University of Maryland, College Park, MD
ESRA, Olney, MD
Search for other works by this author on:
James Pan
University of Maryland, College Park, MD
Andrew Saltos
University of Maryland School of Medicine, Baltimore, MD
Dan Smith
University of Maryland School of Medicine, Baltimore, MD
Arthur Johnson
University of Maryland, College Park, MD
Jafar Vossoughi
University of Maryland, College Park, MD
ESRA, Olney, MD
Paper No:
SBC2011-53366, pp. 825-826; 2 pages
Published Online:
July 17, 2013
Citation
Pan, J, Saltos, A, Smith, D, Johnson, A, & Vossoughi, J. "Validation of Respiratory Resistance Measurements." Proceedings of the ASME 2011 Summer Bioengineering Conference. ASME 2011 Summer Bioengineering Conference, Parts A and B. Farmington, Pennsylvania, USA. June 22–25, 2011. pp. 825-826. ASME. https://doi.org/10.1115/SBC2011-53366
Download citation file:
6
Views
Related Proceedings Papers
Related Articles
The Intake Orifice and a Proposed Method for Testing Exhaust Fans
Trans. ASME (September,1934)
Frequency Response Characteristics of an Active Heat Flux Gage
J. Heat Transfer (August,1998)
Design of a Three-Degree-of-Freedom Robotic Worktable With Prescribed Entire-Motion Characteristics
J. Mech., Trans., and Automation (September,1986)
Related Chapters
Instrument Calibration Methods
Metrology and Instrumentation: Practical Applications for Engineering and Manufacturing
Hot Box Instrumentation, Calibration and Error Estimation — A Survey
Insulation Materials: Testing and Applications, 2nd Volume
A Simple Carburetor
Case Studies in Fluid Mechanics with Sensitivities to Governing Variables