Functional mitral regurgitation (MR) is the consequence of left ventricular dysfunction occurring after ischemic heart disease and often has poor prognosis. Surgical repair and replacement of the mitral valve are currently being used to treat severe functional MR However, the technique carries high mortality rate [1] and is not suitable for patients with comorbidities and advanced age [2]. Recently, a new non-surgical intervention, percutaneous transvenous mitral annuloplasty (PTMA), is emerging as an attractive endovascular alternative that is less invasive, less recovery time, and cost effective. The device is delivered percutaneously into the coronary sinus (CS) vessel and once embedded, it contracts and shortens the septo-lateral distance of the mitral annulus, hence improve MR. However, despite of its feasibility, current clinical trials reported severe adverse events, such as device fracture [3]. The biomechanical interaction between the CS wall and the stent plays a critical role in the outcome of the deployment and the device performance. In this study, we proposed to analyze this interaction by developing Finite Element (FE) models of the CS vessel and the PTMA anchors and analyzing the peak stresses, strains, interaction forces (shear, normal) after the deployment of the proximal and distal anchors into a realistic patient-specific CS model.
Skip Nav Destination
ASME 2011 Summer Bioengineering Conference
June 22–25, 2011
Farmington, Pennsylvania, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-5458-7
PROCEEDINGS PAPER
Simulated Deployment of Percutaneous Transvenous Mitral Annuloplasty Device Into Human Coronary Sinus Vessel
Thuy M. Pham,
Thuy M. Pham
University of Connecticut, Storrs, CT
Search for other works by this author on:
Qian Wang,
Qian Wang
University of Connecticut, Storrs, CT
Search for other works by this author on:
Milton DeHerrera,
Milton DeHerrera
Edwards Lifesciences, Irvine, CA
Search for other works by this author on:
Wei Sun
Wei Sun
University of Connecticut, Storrs, CT
Search for other works by this author on:
Thuy M. Pham
University of Connecticut, Storrs, CT
Qian Wang
University of Connecticut, Storrs, CT
Milton DeHerrera
Edwards Lifesciences, Irvine, CA
Wei Sun
University of Connecticut, Storrs, CT
Paper No:
SBC2011-53851, pp. 255-256; 2 pages
Published Online:
July 17, 2013
Citation
Pham, TM, Wang, Q, DeHerrera, M, & Sun, W. "Simulated Deployment of Percutaneous Transvenous Mitral Annuloplasty Device Into Human Coronary Sinus Vessel." Proceedings of the ASME 2011 Summer Bioengineering Conference. ASME 2011 Summer Bioengineering Conference, Parts A and B. Farmington, Pennsylvania, USA. June 22–25, 2011. pp. 255-256. ASME. https://doi.org/10.1115/SBC2011-53851
Download citation file:
3
Views
Related Proceedings Papers
Biomechanics of Vertebroplasty
IMECE2002
Related Articles
An Efficient and Accurate Prediction of the Stability of Percutaneous Fixation of Acetabular Fractures With Finite Element Simulation
J Biomech Eng (September,2011)
Hydrodynamic Effects of Compliance Mismatch in Stented Arteries
J Biomech Eng (February,2011)
Automated Methodology for Determination of Stress Distribution in Human Abdominal Aortic Aneurysm
J Biomech Eng (October,2005)
Related Chapters
mDFA Human Empirical Results
Modified Detrended Fluctuation Analysis (mDFA)
Introduction and scope
Impedimetric Biosensors for Medical Applications: Current Progress and Challenges
Subsection NCA—General Requirements for Division 1 and Division 2
Companion Guide to the ASME Boiler & Pressure Vessel Codes, Volume 1 Sixth Edition