In vivo studies have revealed that aortic grafts augment heart load and alter blood pressure and flow waveforms [1]. A one-dimensional model of the arterial tree was developed in order to analyze the different mechanisms by which proximal and distal aortic grafts affect hemodynamics. Graft compliance and properties were based on in vitro tests. Predicted pressures at the aortic root were compared for the control, proximal and distal graft case. Pulse pressure increased by 21% and 10% in presence of a proximal and distal graft, respectively. The distal graft resulted in a wave reflection coefficient of 0.62 while for the proximal graft the wave reflection coefficient was 0.46. The physiological mechanism behind the rise of pressure is dual and it is critically affected by the graft’s compliance and position. In case of a proximal graft, the primary reason for aortic pressure increase is the augmentation of aortic characteristic impedance, which augments the forward running pressure wave, while for the distal graft the wave reflections are major contributors to the total pressure wave. Overall, the proximal graft altered hemodynamics to a greater extent than a distal aortic graft.
Skip Nav Destination
ASME 2011 Summer Bioengineering Conference
June 22–25, 2011
Farmington, Pennsylvania, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-5458-7
PROCEEDINGS PAPER
Assessment of Aortic Graft Impact on Hemodynamics
Orestis Vardoulis,
Orestis Vardoulis
Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
Search for other works by this author on:
Eline Coppens,
Eline Coppens
Katholieke Universiteit Leuven, Leuven, Belgium
Search for other works by this author on:
Bryn Martin,
Bryn Martin
Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
Search for other works by this author on:
Philippe Reymond,
Philippe Reymond
Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
Search for other works by this author on:
Nikos Stergiopulos
Nikos Stergiopulos
Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
Search for other works by this author on:
Orestis Vardoulis
Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
Eline Coppens
Katholieke Universiteit Leuven, Leuven, Belgium
Bryn Martin
Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
Philippe Reymond
Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
Nikos Stergiopulos
Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
Paper No:
SBC2011-53245, pp. 181-182; 2 pages
Published Online:
July 17, 2013
Citation
Vardoulis, O, Coppens, E, Martin, B, Reymond, P, & Stergiopulos, N. "Assessment of Aortic Graft Impact on Hemodynamics." Proceedings of the ASME 2011 Summer Bioengineering Conference. ASME 2011 Summer Bioengineering Conference, Parts A and B. Farmington, Pennsylvania, USA. June 22–25, 2011. pp. 181-182. ASME. https://doi.org/10.1115/SBC2011-53245
Download citation file:
4
Views
Related Proceedings Papers
Related Articles
Fluid Structure Interaction With Contact Surface Methodology for Evaluation of Endovascular Carotid Implants for Drug-Resistant Hypertension Treatment
J Biomech Eng (April,2012)
Increased Red Blood Cell Stiffness Increases Pulmonary Vascular Resistance and Pulmonary Arterial Pressure
J Biomech Eng (February,2016)
A Robust and Subject-Specific Hemodynamic Model of the Lower Limb Based on Noninvasive Arterial Measurements
J Biomech Eng (January,2017)
Related Chapters
Two Advanced Methods
Applications of Mathematical Heat Transfer and Fluid Flow Models in Engineering and Medicine
Introduction
Mechanical Blood Trauma in Circulatory-Assist Devices
Hemolysis
Mechanical Blood Trauma in Circulatory-Assist Devices