A new constitutive model for the biomechanical behavior of smooth muscle tissue is employed to investigate the influence of statistical dispersion in the orientation of myosin filaments. The number of activated cross-bridges between the actin and myosin filaments governs the contractile force generated by the muscle and also the contraction speed. A strain-energy function is used to describe the mechanical behavior of the smooth muscle tissue. The predictions from the constitutive model are compared to histological and isometric tensile test results for smooth muscle tissue from swine carotid artery. In order to be able to predict the active stress at different muscle lengths, a filament dispersion significantly larger than the one observed experimentally was required. Furthermore, a comparison of the predicted active stress for a case of uniaxially oriented myosin filaments and a case of filaments with a dispersion based on the experimental histological data shows that the difference in generated stress is noticeable but limited. Thus, the results suggest that myosin filament dispersion alone cannot explain the increase in active muscle stress with increasing muscle stretch.
Skip Nav Destination
ASME 2011 Summer Bioengineering Conference
June 22–25, 2011
Farmington, Pennsylvania, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-5458-7
PROCEEDINGS PAPER
A Theoretical Assessment of the Influence of Myosin Filament Dispersion on Smooth Muscle Contraction
Martin Kroon
Martin Kroon
Royal Institute of Technology, Stockholm, Sweden
Search for other works by this author on:
Martin Kroon
Royal Institute of Technology, Stockholm, Sweden
Paper No:
SBC2011-53071, pp. 145-146; 2 pages
Published Online:
July 17, 2013
Citation
Kroon, M. "A Theoretical Assessment of the Influence of Myosin Filament Dispersion on Smooth Muscle Contraction." Proceedings of the ASME 2011 Summer Bioengineering Conference. ASME 2011 Summer Bioengineering Conference, Parts A and B. Farmington, Pennsylvania, USA. June 22–25, 2011. pp. 145-146. ASME. https://doi.org/10.1115/SBC2011-53071
Download citation file:
4
Views
Related Proceedings Papers
Related Articles
Differential Passive and Active Biaxial Mechanical Behaviors of Muscular and Elastic Arteries: Basilar Versus Common Carotid
J Biomech Eng (May,2011)
3D Mechanical Properties of the Layered Esophagus: Experiment and Constitutive Model
J Biomech Eng (December,2006)
Mechanical Properties and Microstructure of Intraluminal Thrombus From Abdominal Aortic Aneurysm
J Biomech Eng (December,2001)
Related Chapters
Introduction to Stress and Deformation
Introduction to Plastics Engineering
Models for Solid Materials
Introduction to Plastics Engineering
Electrochemical impedance spectroscopy
Impedimetric Biosensors for Medical Applications: Current Progress and Challenges