A commonly accepted treatment method for scaphoid fractures is dorsal percutaneous fixation [1, 2]. This has been shown to decrease the need for cast immobilization and allow faster recovery [3, 4]. For this approach a central screw placement is critical as it provides greater stiffness and load to failure, and allows a longer screw to be inserted which increases screw compression. All of these factors aid in fracture union [5]. However, the complex shape of the scaphoid bone makes central screw placement difficult, as the main axis cannot be easily visualized. Currently, scaphoid screws are placed using K wires guided under 2D fluoroscopy; however, intra-operative 3D fluoroscopy, which can create a CT reconstruction, is becoming more readily available. The goals of this study are to see if there is a significant difference between 2D and 3D fluoroscopic imaging in measuring screw malpositioning (distance off-center) and if there is a difference in repeatability.
Skip Nav Destination
ASME 2010 Summer Bioengineering Conference
June 16–19, 2010
Naples, Florida, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-4403-8
PROCEEDINGS PAPER
Three Dimensional Fluoroscan is More Accurate and Repeatable Than Two Dimensional Fluoroscan for Measuring Central Scaphoid Screw Placement in a Cadaver Model Available to Purchase
Hyun Kyu Han,
Hyun Kyu Han
UCSF/SFGH Orthopaedic Trauma Institute, San Francisco, CA
University of California, San Francisco, San Francisco, CA
Search for other works by this author on:
W. Scott Green,
W. Scott Green
University of California, San Francisco, San Francisco, CA
Search for other works by this author on:
Jenni M. Buckley,
Jenni M. Buckley
UCSF/SFGH Orthopaedic Trauma Institute, San Francisco, CA
University of California, San Francisco, San Francisco, CA
Search for other works by this author on:
Lisa L. Lattanza
Lisa L. Lattanza
University of California, San Francisco, San Francisco, CA
Search for other works by this author on:
Hyun Kyu Han
UCSF/SFGH Orthopaedic Trauma Institute, San Francisco, CA
University of California, San Francisco, San Francisco, CA
W. Scott Green
University of California, San Francisco, San Francisco, CA
Jenni M. Buckley
UCSF/SFGH Orthopaedic Trauma Institute, San Francisco, CA
University of California, San Francisco, San Francisco, CA
Lisa L. Lattanza
University of California, San Francisco, San Francisco, CA
Paper No:
SBC2010-19084, pp. 801-802; 2 pages
Published Online:
July 15, 2013
Citation
Han, HK, Green, WS, Buckley, JM, & Lattanza, LL. "Three Dimensional Fluoroscan is More Accurate and Repeatable Than Two Dimensional Fluoroscan for Measuring Central Scaphoid Screw Placement in a Cadaver Model." Proceedings of the ASME 2010 Summer Bioengineering Conference. ASME 2010 Summer Bioengineering Conference, Parts A and B. Naples, Florida, USA. June 16–19, 2010. pp. 801-802. ASME. https://doi.org/10.1115/SBC2010-19084
Download citation file:
6
Views
Related Proceedings Papers
Related Articles
High Speed Fracture Fixation: Assessing Resulting Fixation Stability and Fastener Withdrawal Strength
J Biomech Eng (September,2013)
Factors Affecting the Pullout Strength of Cancellous Bone Screws
J Biomech Eng (August,1996)
Development of an Inertia-Driven Model of Sideways Fall for Detailed Study of Femur Fracture Mechanics
J Biomech Eng (December,2013)
Related Chapters
Introduction and Definitions
Handbook on Stiffness & Damping in Mechanical Design
Radial Delayed Hydride Cracking in Irradiated Zircaloy-2 Cladding: Advanced Characterization Techniques
Zirconium in the Nuclear Industry: 20th International Symposium
Simple Structural Elements