The aim of this research project is to test the feasibility of using low-power radio frequency (RF) radiation operating in the millimeter wave (MMW) range and non-contact infrared temperature acquisition to measure skin blood-flow rates. MMW is the band of the electromagnetic spectrum from 30 to 300 GHZ. It has been shown that millimeter waves will cause a local temperature rise in the skin, without the harmful effects of ionizing radiation [1]. Skin blood flow is a physiological variable that is essential in the assessment of many diseases, such as diabetes, and can also be the determining factor in many other heat-related body functions (i.e. hot flashes in menopausal women) and malfunctions (i.e. heat stroke) [2]. However, there is currently no non-invasive and non-contact means of measuring actual skin blood flow rates in a patient. During this research, millimeter waves at 35 GHz are being used to superficially heat the skin tissues of a rabbit ear. Simultaneous, non-contacting measurement of skin surface temperature could allow the inference of the rate of blood flow to the tissue, based on observed relationships between surface temperature and skin perfusion rates during MMW irradiation at 35 GHz [1, 3].
Skip Nav Destination
ASME 2009 Summer Bioengineering Conference
June 17–21, 2009
Lake Tahoe, California, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-4891-3
PROCEEDINGS PAPER
Surface Temperature Response to Millimeter Wave Exposure as an Indicator of Skin Blood Flow
Carmen D. Zirlott,
Carmen D. Zirlott
University of South Alabama, Mobile, AL
Search for other works by this author on:
David A. Nelson
David A. Nelson
University of South Alabama, Mobile, AL
Search for other works by this author on:
Carmen D. Zirlott
University of South Alabama, Mobile, AL
David A. Nelson
University of South Alabama, Mobile, AL
Paper No:
SBC2009-206747, pp. 767-768; 2 pages
Published Online:
July 19, 2013
Citation
Zirlott, CD, & Nelson, DA. "Surface Temperature Response to Millimeter Wave Exposure as an Indicator of Skin Blood Flow." Proceedings of the ASME 2009 Summer Bioengineering Conference. ASME 2009 Summer Bioengineering Conference, Parts A and B. Lake Tahoe, California, USA. June 17–21, 2009. pp. 767-768. ASME. https://doi.org/10.1115/SBC2009-206747
Download citation file:
8
Views
Related Proceedings Papers
Related Articles
A Totally Implantable Hearing Device for Restoration of Hearing
J. Med. Devices (June,2008)
Experimental Measurements of the Temperature Variation Along Artery-Vein Pairs from 200 to 1000 μm Diameter in Rat Hind Limb
J Biomech Eng (December,2002)
Bioheat Transfer Basis of Human Thermoregulation: Principles and Applications
J. Heat Transfer (March,2022)
Related Chapters
Human Thermal Comfort
Electromagnetic Waves and Heat Transfer: Sensitivites to Governing Variables in Everyday Life
Introduction and scope
Impedimetric Biosensors for Medical Applications: Current Progress and Challenges
Compact Ultra-Wideband Antenna with Dual Band-Notches for WiMAX and Upper WLAN Band
International Conference on Computer and Computer Intelligence (ICCCI 2011)