The design of the femoral components used in hip arthroplasty has evolved from a concept to a standard construct with a few variations. Attempts to remove less bone have become more important as revision surgery many years after primary implantation has become more common. The Mayo Conservative Hip Prosthesis (Zimmer, Inc., Warsaw, IN) was designed to preserve bone and to use broaches that do not require strict superior/inferior access to the femoral canal. The shape of the stem was intended to reduce the amount of subsidence following implantation. The taper in both the anterior-posterior and medial-lateral directions offered an interference fit to ensure rigidity. The VerSys Fiber Metal Taper (FMT) implant (Zimmer, Inc., Warsaw, IN) is a tapered, collarless implant that is coated proximally with fiber metal and has a polished distal tip. It is intended to be inserted without cement and has a successful history of clinical use. Preparation of the canal requires more superior/inferior access for broaching and preparation of the femur.
Skip Nav Destination
ASME 2009 Summer Bioengineering Conference
June 17–21, 2009
Lake Tahoe, California, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-4891-3
PROCEEDINGS PAPER
A Comparison of Two Hip Stem Styles: Subsidence, Failure Load, and Bone Density
Laurel Kuxhaus,
Laurel Kuxhaus
Allegheny General Hospital, Pittsburgh, PA
Search for other works by this author on:
Derek Dazen,
Derek Dazen
Allegheny General Hospital, Pittsburgh, PA
Search for other works by this author on:
Andre Hofer,
Andre Hofer
Orthopädische Chirurgie, Greifswald, Germany
Search for other works by this author on:
Nicholas G. Sotereanos,
Nicholas G. Sotereanos
Allegheny General Hospital, Pittsburgh, PA
Search for other works by this author on:
Mark Carl Miller
Mark Carl Miller
Allegheny General Hospital, Pittsburgh, PA
University of Pittsburgh, Pittsburgh, PA
Search for other works by this author on:
Laurel Kuxhaus
Allegheny General Hospital, Pittsburgh, PA
Derek Dazen
Allegheny General Hospital, Pittsburgh, PA
Andre Hofer
Orthopädische Chirurgie, Greifswald, Germany
Nicholas G. Sotereanos
Allegheny General Hospital, Pittsburgh, PA
Mark Carl Miller
Allegheny General Hospital, Pittsburgh, PA
University of Pittsburgh, Pittsburgh, PA
Paper No:
SBC2009-204300, pp. 371-372; 2 pages
Published Online:
July 19, 2013
Citation
Kuxhaus, L, Dazen, D, Hofer, A, Sotereanos, NG, & Miller, MC. "A Comparison of Two Hip Stem Styles: Subsidence, Failure Load, and Bone Density." Proceedings of the ASME 2009 Summer Bioengineering Conference. ASME 2009 Summer Bioengineering Conference, Parts A and B. Lake Tahoe, California, USA. June 17–21, 2009. pp. 371-372. ASME. https://doi.org/10.1115/SBC2009-204300
Download citation file:
7
Views
Related Proceedings Papers
Related Articles
The Design of a Continuous Fiber Composite Surface Hip Replacement
J. Mech. Des (October,1980)
Effects of Fit and Bonding Characteristics of Femoral Stems on Adaptive Bone Remodeling
J Biomech Eng (November,1994)
Evaluation of Bone Cement Failure Criteria With Applications to the Acetabular Region
J Biomech Eng (November,1983)
Related Chapters
Novel and Efficient Mathematical and Computational Methods for the Analysis and Architecting of Ultralight Cellular Materials and their Macrostructural Responses
Advances in Computers and Information in Engineering Research, Volume 2
Introduction and Definitions
Handbook on Stiffness & Damping in Mechanical Design
Part III Some Practical Advice
The Elements of Mechanical Design