In this work we carry out an in vivo validation of a method for estimating blood flow rate from the peak velocity, as it is usually done in single-wire Doppler catheter measurements. This method, originally proposed in [1] stems from the application of numerical analysis of the blood flow with Computational Fluid Dynamics (CFD) techniques. It proposes a new formula linking the maximum velocity and the flow rate, which, however, has the same practical cost of classical approaches based on a priori assumptions on the velocity profile. After the first clinical observations indicating the improved accuracy in flow rate estimates introduced by the new method discussed in [2, 3], in this paper we present an ad hoc in vivo validation, as firstly suggested in [4], still confirming the reliability of the new approach.
Skip Nav Destination
ASME 2009 Summer Bioengineering Conference
June 17–21, 2009
Lake Tahoe, California, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-4891-3
PROCEEDINGS PAPER
Computational Fluid Dynamics-Based Estimation of Blood Flow Rate in Doppler Analysis: In Vivo Validation by Means of Phase Contrast Magnetic Resonance Imaging
Raffaele Ponzini,
Raffaele Ponzini
CILEA, Segrate, MI, Italy
Search for other works by this author on:
Christian Vergara,
Christian Vergara
Università degli Studi di Bergamo, Bergamo, Italy
Search for other works by this author on:
Alessandro Veneziani,
Alessandro Veneziani
Emory University, Atlanta, GA
Search for other works by this author on:
Alberto Redaelli,
Alberto Redaelli
Politecnico di Milano, Milan, Italy
Search for other works by this author on:
Angelo Vanzulli,
Angelo Vanzulli
Ospedale Niguarda Ca’ Granda, Milan, Italy
Search for other works by this author on:
Oberdan Parodi
Oberdan Parodi
CNR, Pisa, Italy
Search for other works by this author on:
Raffaele Ponzini
CILEA, Segrate, MI, Italy
Christian Vergara
Università degli Studi di Bergamo, Bergamo, Italy
Giovanna Rizzo
CNR, Milan, Italy
Alessandro Veneziani
Emory University, Atlanta, GA
Alberto Redaelli
Politecnico di Milano, Milan, Italy
Angelo Vanzulli
Ospedale Niguarda Ca’ Granda, Milan, Italy
Oberdan Parodi
CNR, Pisa, Italy
Paper No:
SBC2009-205522, pp. 227-228; 2 pages
Published Online:
July 19, 2013
Citation
Ponzini, R, Vergara, C, Rizzo, G, Veneziani, A, Redaelli, A, Vanzulli, A, & Parodi, O. "Computational Fluid Dynamics-Based Estimation of Blood Flow Rate in Doppler Analysis: In Vivo Validation by Means of Phase Contrast Magnetic Resonance Imaging." Proceedings of the ASME 2009 Summer Bioengineering Conference. ASME 2009 Summer Bioengineering Conference, Parts A and B. Lake Tahoe, California, USA. June 17–21, 2009. pp. 227-228. ASME. https://doi.org/10.1115/SBC2009-205522
Download citation file:
6
Views
Related Proceedings Papers
Related Articles
In Vitro Quantification of Time Dependent Thrombus Size Using Magnetic Resonance Imaging and Computational Simulations of Thrombus Surface Shear Stresses
J Biomech Eng (July,2014)
Steerable Guidewire for Magnetic Resonance Guided Endovascular Interventions
J. Med. Devices (June,2014)
Influence of Hemodialysis Catheter Insertion on Hemodynamics in the Central Veins
J Biomech Eng (September,2020)
Related Chapters
Completing the Picture
Air Engines: The History, Science, and Reality of the Perfect Engine
Dynamic Behavior of Pumping Systems
Pipeline Pumping and Compression System: A Practical Approach, Third Edition
Dynamic Behavior of Pumping Systems
Pipeline Pumping and Compression Systems: A Practical Approach