End Stage Renal Disease (ESRD) is the degeneration of kidney function to remove uremic toxins from the blood. Currently there are over 484,000 sufferers of ESRD in the United States, with this figure predicted to rise to over 800,000 by 2020 [1]. The total cost of care for patients with ESRD was estimated to exceed 1 billion dollars in the United States [2]. A kidney transplant is the ideal solution for ESRD patients; however with the increasing number of ESRD patients the odds of receiving a donor kidney are poor. The alternative is hemodialysis. This process is involves the extraction of blood from the patient to an extracorporal machine. Blood is pumped at a rate of 350 mL/min to ensure effective dialysis. The blood is then returned to the body cleaned. The gold standard for hemodialysis access is the native arteriovenous fistula [3] with the most common type being the Brescia-Cimino fistula at the wrist [4]. In some subgroups the fistula performs poorly. In diabetics and the elderly, specifically over 70s [2] or can’t be constructed because of unsuitable blood vessels [5]. In this case an alternative is the synthetic AV graft. Made of polytetrafluoroethelyne, it has lower patency rates against the fistula [6] [7] mediated by the susceptibility to thrombosis induced by stenosis development and infection [7].The majority of stenosis development is within the venous anastomosis (kanterman1995). The formation of intimal hyperplasia (IH) leading to stenosis formation is caused by smooth cell proliferation and migration as a result of endothelial cells reacting to shear stress receptors. The development of IH has been linked to local hemodynamics and turbulence in the flow, which in turn are heavily influenced by the geometry of the graft.
Skip Nav Destination
ASME 2009 Summer Bioengineering Conference
June 17–21, 2009
Lake Tahoe, California, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-4891-3
PROCEEDINGS PAPER
Geometric Enhancements of an Arteriovenous Graft
Stephen P. Broderick,
Stephen P. Broderick
University of Limerick, Limerick, Ireland
Search for other works by this author on:
Gráinne Carroll,
Gráinne Carroll
University of Limerick, Limerick, Ireland
Search for other works by this author on:
Micheal Walsh
Micheal Walsh
University of Limerick, Limerick, Ireland
Search for other works by this author on:
Stephen P. Broderick
University of Limerick, Limerick, Ireland
Gráinne Carroll
University of Limerick, Limerick, Ireland
Micheal Walsh
University of Limerick, Limerick, Ireland
Paper No:
SBC2009-206863, pp. 1169-1170; 2 pages
Published Online:
July 19, 2013
Citation
Broderick, SP, Carroll, G, & Walsh, M. "Geometric Enhancements of an Arteriovenous Graft." Proceedings of the ASME 2009 Summer Bioengineering Conference. ASME 2009 Summer Bioengineering Conference, Parts A and B. Lake Tahoe, California, USA. June 17–21, 2009. pp. 1169-1170. ASME. https://doi.org/10.1115/SBC2009-206863
Download citation file:
5
Views
Related Proceedings Papers
Related Articles
Mathematical Model for Pressure Losses in the Hemodialysis Graft Vascular Circuit
J Biomech Eng (February,2005)
Computational Modeling of Blood Hydrodynamics and Blockage Formation Phenomena in the Human Cardiovascular System
J. Med. Devices (June,2010)
Influence of Hemodialysis Catheter Insertion on Hemodynamics in the Central Veins
J Biomech Eng (September,2020)
Related Chapters
Introduction
Mechanical Blood Trauma in Circulatory-Assist Devices
Concluding remarks
Mechanical Blood Trauma in Circulatory-Assist Devices
Clinical issues and experience
Mechanical Blood Trauma in Circulatory-Assist Devices