Due to a high mortality rate for pediatric patients on the heart transplant list, smaller versions of ventricular assist devices (VADs) are being developed for these patients [1]. Ventricular assist devicess used in adult patients with end-stage heart failure have already become a viable option during the bridge-to-transplant period [2] and have also shown potential for aiding in myocardial recovery. A challenge to the development of pediatric VADs is the use of the aortic cannulae attached to them. During the development of the 12cc Pennsylvania State pediatric pulsatile VAD, particle image velocimetry (PIV) illustrated that hematocrit levels affected the fluid dynamics. The objective of this study is to compare the fluid dynamics of a pediatric blood analog and a goat blood analog within PVAD aortic cannulae.
Skip Nav Destination
ASME 2008 Summer Bioengineering Conference
June 25–29, 2008
Marco Island, Florida, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-4321-5
PROCEEDINGS PAPER
Using Animal Models to Study Pediatric Cardiovascular Devices: The Impact on Fluid Dynamics
Tobias C. Long,
Tobias C. Long
Pennsylvania State University, University Park, PA
Search for other works by this author on:
Michael V. Perone,
Michael V. Perone
Pennsylvania State University, University Park, PA
Search for other works by this author on:
Steven Deutsch,
Steven Deutsch
Pennsylvania State University, University Park, PA
Search for other works by this author on:
Keefe B. Manning
Keefe B. Manning
Pennsylvania State University, University Park, PA
Search for other works by this author on:
Tobias C. Long
Pennsylvania State University, University Park, PA
Michael V. Perone
Pennsylvania State University, University Park, PA
Steven Deutsch
Pennsylvania State University, University Park, PA
Keefe B. Manning
Pennsylvania State University, University Park, PA
Paper No:
SBC2008-192747, pp. 977-978; 2 pages
Published Online:
March 13, 2014
Citation
Long, TC, Perone, MV, Deutsch, S, & Manning, KB. "Using Animal Models to Study Pediatric Cardiovascular Devices: The Impact on Fluid Dynamics." Proceedings of the ASME 2008 Summer Bioengineering Conference. ASME 2008 Summer Bioengineering Conference, Parts A and B. Marco Island, Florida, USA. June 25–29, 2008. pp. 977-978. ASME. https://doi.org/10.1115/SBC2008-192747
Download citation file:
7
Views
Related Proceedings Papers
Related Articles
A Proof-of-Concept Demonstration for a Novel Soft Ventricular Assist Device
J. Med. Devices (June,2019)
Ventricular Assist Devices: Current State and Challenges
J. Med. Devices (December,2017)
An In Vitro Fluid Dynamic Study of Pediatric Cannulae: The Value of Animal Studies to Predict Human Flow
J Biomech Eng (April,2012)
Related Chapters
Introduction
Design of Mechanical Bearings in Cardiac Assist Devices
Introduction
Mechanical Blood Trauma in Circulatory-Assist Devices
Generating Synthetic Electrocardiogram Signals Withcontrolled Temporal and Spectral Characteristics
Intelligent Engineering Systems through Artificial Neural Networks Volume 18