Angiography is widely used diagnostic method to find the ischemic severity. However, it is limited in its capacity in determining the functional severity of the stenosis [1]. Hence, a functional diagnostic parameter Fractional Flow Reserve (FFR), defined as the ratio of distal pressure to the proximal pressure at maximum vasodilation [2], at the site of the stenosis, was developed to assess the functional severity of the stenosis. Pijls et al [3], established a threshold value of 0.75 for FFR, based on which coronary intervention decisions are taken. If FFR is below 0.75, a percutaneous coronary intervention is recommended. FFR is calculated during cardiac catheterization by measuring the pressure values across the stenosis. However, the value of FFR measured during cardiac catheterization doesn’t account for the increase in pressure values downstream of stenosis, due to other resistances in coronary circuit, e.g., abnormal microvasculature and functional collaterals, as it cannot delineate the effect of downstream collateral flow or the presence of myocardial diseases.
Skip Nav Destination
ASME 2008 Summer Bioengineering Conference
June 25–29, 2008
Marco Island, Florida, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-4321-5
PROCEEDINGS PAPER
Misinterpretation of Functional Severity of Coronary Stenosis in the Presence of Collateral Flow
Srikara Viswanath Peelukhana,
Srikara Viswanath Peelukhana
University of Cincinnati, Cincinnati, OH
Search for other works by this author on:
Rupak K. Banerjee,
Rupak K. Banerjee
University of Cincinnati, Cincinnati, OH
Search for other works by this author on:
Mohamed A. Effat,
Mohamed A. Effat
University of Cincinnati, Cincinnati, OH
Search for other works by this author on:
Tarek Helmy
Tarek Helmy
University of Cincinnati, Cincinnati, OH
Search for other works by this author on:
Srikara Viswanath Peelukhana
University of Cincinnati, Cincinnati, OH
Rupak K. Banerjee
University of Cincinnati, Cincinnati, OH
Mohamed A. Effat
University of Cincinnati, Cincinnati, OH
Tarek Helmy
University of Cincinnati, Cincinnati, OH
Paper No:
SBC2008-193034, pp. 585-586; 2 pages
Published Online:
March 13, 2014
Citation
Peelukhana, SV, Banerjee, RK, Effat, MA, & Helmy, T. "Misinterpretation of Functional Severity of Coronary Stenosis in the Presence of Collateral Flow." Proceedings of the ASME 2008 Summer Bioengineering Conference. ASME 2008 Summer Bioengineering Conference, Parts A and B. Marco Island, Florida, USA. June 25–29, 2008. pp. 585-586. ASME. https://doi.org/10.1115/SBC2008-193034
Download citation file:
4
Views
Related Articles
Microfabrication of a Device to Evaluate the Swelling of Glucose Sensitive Hydrogels Under Isochoric Conditions
J. Med. Devices (June,2009)
Mathematical Model for Pressure Losses in the Hemodialysis Graft Vascular Circuit
J Biomech Eng (February,2005)
That Hemodynamics and Not Material Mismatch is of Primary Concern in Bypass Graft Failure: An Experimental Argument
J Biomech Eng (October,2005)
Related Chapters
The Design of a New Bluetooth Adapter
International Conference on Advanced Computer Theory and Engineering, 5th (ICACTE 2012)
Siphon Seals and Water Legs
Hydraulics, Pipe Flow, Industrial HVAC & Utility Systems: Mister Mech Mentor, Vol. 1
Occlusion Identification and Relief within Branched Structures
Biomedical Applications of Vibration and Acoustics in Therapy, Bioeffect and Modeling