The musculotendon moment arm (MA) is the perpendicular distance from a muscle’s line of action to the rotational center of a joint. Moment arms are important in muscle modeling [1], and thus their accuracy is of great importance. Current in vivo techniques for computing MAs include the center of rotation and tendon excursion methods [1, 2]. The tendon excursion (TE) method relates the change in musculotendon length to an angular change in joint position [3]. This requires two measurements of musculotendon length for each MA computed. Similarly, the center of rotation method requires multiple image-based geometry measurements to compute the MA for a specific joint angle. The TE and center of rotation methods are both prone to measurement error, and thus it is difficult to ascertain the accuracy of the resulting MA. In this paper we present a novel hybrid methodology combining ultrasound (US) and video-based motion capture to compute the Achilles tendon moment arm. An advantage of this approach is that data used to derive the MA are acquired using highly accurate and reliable measurement instruments (i.e, US & motion capture), which may improve the accuracy of the MA estimate. The purpose of this paper is to present the hybrid methodology and validation results based on testing the method using an animal model.
Skip Nav Destination
ASME 2008 Summer Bioengineering Conference
June 25–29, 2008
Marco Island, Florida, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-4321-5
PROCEEDINGS PAPER
Estimation of Achilles Tendon Moment Arms In Vivo: A Novel Hybrid Method Using Ultrasound and Motion Analysis
Justin D. Cowder,
Justin D. Cowder
University of Delaware, Newark, DE
Search for other works by this author on:
Nicole J. Chimera,
Nicole J. Chimera
University of Delaware, Newark, DE
Search for other works by this author on:
Thomas S. Buchanan,
Thomas S. Buchanan
University of Delaware, Newark, DE
Search for other works by this author on:
Kurt T. Manal
Kurt T. Manal
University of Delaware, Newark, DE
Search for other works by this author on:
Justin D. Cowder
University of Delaware, Newark, DE
Nicole J. Chimera
University of Delaware, Newark, DE
Thomas S. Buchanan
University of Delaware, Newark, DE
Kurt T. Manal
University of Delaware, Newark, DE
Paper No:
SBC2008-193137, pp. 1111-1112; 2 pages
Published Online:
March 13, 2014
Citation
Cowder, JD, Chimera, NJ, Buchanan, TS, & Manal, KT. "Estimation of Achilles Tendon Moment Arms In Vivo: A Novel Hybrid Method Using Ultrasound and Motion Analysis." Proceedings of the ASME 2008 Summer Bioengineering Conference. ASME 2008 Summer Bioengineering Conference, Parts A and B. Marco Island, Florida, USA. June 25–29, 2008. pp. 1111-1112. ASME. https://doi.org/10.1115/SBC2008-193137
Download citation file:
6
Views
Related Proceedings Papers
Related Articles
The Sprinter's Foot
Mechanical Engineering (October,2009)
Time-Dependent Ultrasound Echo Changes Occur in Tendon During Viscoelastic Testing
J Biomech Eng (November,2012)
Design and Validation of a General Purpose Robotic Testing System for Musculoskeletal Applications
J Biomech Eng (February,2010)
Related Chapters
Tendon End Anchor Testing
Commentary on Articles CC-2000, CC-3000 and CC-4000
Appendix F—Tendon End Anchor Testing
Commentary on Article CC-3000 Design
The Testing and Instrumentation of Stone Columns
Deep Foundation Improvements: Design, Construction, and Testing