Native heart valves with limited functionality are commonly replaced by prosthetic heart valves. Since the first heart valve replacement in 1960, more than three million valves have been implanted worldwide. The most widely implanted prosthetic heart valve design is currently the bileaflet mechanical heart valve (BMHV), with more than 130,000 implants every year worldwide. However, studies have shown that this valve design can still cause major complications, including hemolysis, platelet activation, and thromboembolic events. Clinical reports and recent in vitro experiments suggest that these thrombogenic complications are associated with the hemodynamic stresses imposed on blood elements by the complex non-physiologic flow induced by the valve, in particular in the hinge region.
Skip Nav Destination
ASME 2008 Summer Bioengineering Conference
June 25–29, 2008
Marco Island, Florida, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-4321-5
PROCEEDINGS PAPER
Simulations of the Hinge Flow Fields of a Bileaflet Mechanical Heart Valve Under Physiologic Pulsatile Aortic Conditions
Hélène A. Simon,
Hélène A. Simon
Georgia Institute of Technology, Atlanta, GA
Search for other works by this author on:
Liang Ge,
Liang Ge
St. Anthony Fall Laboratory, Minneapolis, MN
Search for other works by this author on:
Iman Borazjani,
Iman Borazjani
St. Anthony Fall Laboratory, Minneapolis, MN
Search for other works by this author on:
Fotis Sotiropoulos,
Fotis Sotiropoulos
St. Anthony Fall Laboratory, Minneapolis, MN
Search for other works by this author on:
Ajit P. Yoganathan
Ajit P. Yoganathan
Georgia Institute of Technology, Atlanta, GA
Search for other works by this author on:
Hélène A. Simon
Georgia Institute of Technology, Atlanta, GA
Liang Ge
St. Anthony Fall Laboratory, Minneapolis, MN
Iman Borazjani
St. Anthony Fall Laboratory, Minneapolis, MN
Fotis Sotiropoulos
St. Anthony Fall Laboratory, Minneapolis, MN
Ajit P. Yoganathan
Georgia Institute of Technology, Atlanta, GA
Paper No:
SBC2008-192939, pp. 1093-1094; 2 pages
Published Online:
March 13, 2014
Citation
Simon, HA, Ge, L, Borazjani, I, Sotiropoulos, F, & Yoganathan, AP. "Simulations of the Hinge Flow Fields of a Bileaflet Mechanical Heart Valve Under Physiologic Pulsatile Aortic Conditions." Proceedings of the ASME 2008 Summer Bioengineering Conference. ASME 2008 Summer Bioengineering Conference, Parts A and B. Marco Island, Florida, USA. June 25–29, 2008. pp. 1093-1094. ASME. https://doi.org/10.1115/SBC2008-192939
Download citation file:
7
Views
Related Proceedings Papers
Related Articles
Comparison of the Hemodynamic and Thrombogenic Performance of Two Bileaflet Mechanical Heart Valves Using a CFD/FSI Model
J Biomech Eng (August,2007)
Vortex Shedding as a Mechanism for Free Emboli Formation in Mechanical Heart Valves
J Biomech Eng (April,2000)
Design of a Pulsatile Flow Facility to Evaluate Thrombogenic Potential of Implantable Cardiac Devices
J Biomech Eng (April,2015)
Related Chapters
Introduction
Mechanical Blood Trauma in Circulatory-Assist Devices
Two Advanced Methods
Applications of Mathematical Heat Transfer and Fluid Flow Models in Engineering and Medicine
Hemolysis
Mechanical Blood Trauma in Circulatory-Assist Devices