Computer-aided medical technologies are currently restricted by the limited understanding of the mechanical response of solid abdominal organs to finite loading conditions typical of surgical manipulation [5]. This limitation is a result of the difficulty in acquiring the necessary data on whole organs. To develop a constitutive model capable of predicting complex surgical scenarios, multiple testing modalities need to be simultaneously obtained to capture the fundamental nature of the tissue’s behavior under such conditions. In vivo tests are essential to obtain a realistic response, but their inherent difficulty and unknown boundary conditions makes them an impractical approach. Ex vivo tests are easy to control, but the response is unrealistic. A perfusion apparatus was previously developed that obtained near in vivo conditions for whole livers while allowing the ease of ex vivo testing [3]. This work presents the results from complete viscoelastic testing of whole-perfused livers with surgically relevant time-dependant indentation loading profiles to 35% nominal strain. These results will aid in the development of a constitutive model for the liver whose parameters can be related to the physical constituents of the tissue. As an intermediate modeling step, a 1D rheological modeling tool was used to identify the form and initial parameters for a constitutive model.
Skip Nav Destination
ASME 2007 Summer Bioengineering Conference
June 20–24, 2007
Keystone, Colorado, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
0-7918-4798-5
PROCEEDINGS PAPER
Viscoelastic Characterization of Perfused Liver: Indentation Testing and Preliminary Modeling
Amy E. Kerdok,
Amy E. Kerdok
Massachusetts Institute of Technology, Cambridge, MA
Search for other works by this author on:
Robert D. Howe,
Robert D. Howe
Harvard University, Cambridge, MA
Search for other works by this author on:
Simona Socrate
Simona Socrate
Massachusetts Institute of Technology, Cambridge, MA
Search for other works by this author on:
Amy E. Kerdok
Massachusetts Institute of Technology, Cambridge, MA
Robert D. Howe
Harvard University, Cambridge, MA
Simona Socrate
Massachusetts Institute of Technology, Cambridge, MA
Paper No:
SBC2007-176645, pp. 951-952; 2 pages
Published Online:
March 12, 2014
Citation
Kerdok, AE, Howe, RD, & Socrate, S. "Viscoelastic Characterization of Perfused Liver: Indentation Testing and Preliminary Modeling." Proceedings of the ASME 2007 Summer Bioengineering Conference. ASME 2007 Summer Bioengineering Conference. Keystone, Colorado, USA. June 20–24, 2007. pp. 951-952. ASME. https://doi.org/10.1115/SBC2007-176645
Download citation file:
2
Views
Related Proceedings Papers
Related Articles
Identifying a Minimal Rheological Configuration: A Tool for Effective and Efficient Constitutive Modeling of Soft Tissues
J Biomech Eng (April,2011)
Pre-Clinical Evaluation of Direct Current Ablation for the Treatment of Benign Prostatic Hyperplasia
J. Med. Devices (June,2009)
Monopolar Electrosurgical Thermal Management System to Reduce Lateral Thermal Damage During Surgery
J. Med. Devices (June,2010)
Related Chapters
Role of Artificial Intelligence in Hepatitis B Diagnosis
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3
Bioinformatic Analysis of the Malay Peninsular Macaca Fascicularis Based on Cytochrome C Oxidase I Sequences
International Conference on Computer Research and Development, 5th (ICCRD 2013)
Introduction and scope
Impedimetric Biosensors for Medical Applications: Current Progress and Challenges