Joint instability may lead to modified and excessive mechanical stresses on the articular surfaces. This repetitive, chronic mechanical overload is one possible source behind the initiation and progression of osteoarthritis (OA). However, the mechanisms by which excessive mechanical force may lead to OA remain unknown. It has been proposed that a change in the location of load bearing regions following joint instability may initiate OA, while the progression of OA is driven by increased tangential shear loading [1]. In addition to changing the load location, joint instability may modify bone kinematics, and in turn articulating surface interactions (e.g. sliding, pivoting and rolling contacts). These altered surface interactions may result in novel and damaging loading applied to the articular cartilage.
Skip Nav Destination
ASME 2007 Summer Bioengineering Conference
June 20–24, 2007
Keystone, Colorado, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
0-7918-4798-5
PROCEEDINGS PAPER
Cartilage Damage in the Unstable Knee is Related to Tibio-Femoral Contact Mechanics
William J. Anderst,
William J. Anderst
University of Pittsburgh, Pittsburgh, PA
Search for other works by this author on:
Scott Tashman
Scott Tashman
University of Pittsburgh, Pittsburgh, PA
Search for other works by this author on:
William J. Anderst
University of Pittsburgh, Pittsburgh, PA
Scott Tashman
University of Pittsburgh, Pittsburgh, PA
Paper No:
SBC2007-175841, pp. 633-634; 2 pages
Published Online:
March 12, 2014
Citation
Anderst, WJ, & Tashman, S. "Cartilage Damage in the Unstable Knee is Related to Tibio-Femoral Contact Mechanics." Proceedings of the ASME 2007 Summer Bioengineering Conference. ASME 2007 Summer Bioengineering Conference. Keystone, Colorado, USA. June 20–24, 2007. pp. 633-634. ASME. https://doi.org/10.1115/SBC2007-175841
Download citation file:
6
Views
Related Proceedings Papers
Dynamic Modeling of Knee Mechanics
IMECE2011
Related Articles
Chondrocyte Damage and Contact Pressures Following Impact on the Rabbit Tibiofemoral Joint
J Biomech Eng (August,2008)
Computationally Efficient Finite Element Evaluation of Natural Patellofemoral Mechanics
J Biomech Eng (December,2010)
Design of Reverse Materials Resurfacing Implants for Mild–Moderate Medial Osteoarthritis of the Knee
J. Med. Devices (March,2017)
Related Chapters
Hydrodynamic Lubrication
Design of Mechanical Bearings in Cardiac Assist Devices
Introduction to Contact Problems in Structural Mechanics
Contact in Structural Mechanics: A Weighted Residual Approach
Sthenics of Contact
Contact in Structural Mechanics: A Weighted Residual Approach