The mitral valve apparatus is a complex structure with multiple components that require seamless, integrated operation for normal valve function. One of these components is the annulus, a fibrous ring of tissue that defines the boundary between the mitral valve leaflets and the surrounding superstructure of the heart. During the cardiac cycle the annulus undergoes large deformations and dramatic shape changes. Moreover, the annulus motion represents a key boundary condition for mitral valve leaflet deformation. Yet, to date our knowledge of the subtle deformations this structure undergoes during the cardiac cycle remains very limited. In the present study, an array of 1 mm diameter piezoelectric sonocrystals was implanted in 5 sheep to quantify annular deformation over the complete cardiac cycle. These crystals act as fiducial markers for the mitral annulus with a temporal resolution of ∼1ms and a special resolution of .01mm in a calibrated three dimensional space. A quintic order generalized 3D spline was developed to reconstruct the annular geometry.
Skip Nav Destination
ASME 2007 Summer Bioengineering Conference
June 20–24, 2007
Keystone, Colorado, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
0-7918-4798-5
PROCEEDINGS PAPER
In Vivo Dynamic Strains of the Mitral Valve Annulus
Brett Zubiate,
Brett Zubiate
University of Pittsburgh, Pittsburgh, PA
Search for other works by this author on:
Michael Sacks,
Michael Sacks
University of Pittsburgh, Pittsburgh, PA
Search for other works by this author on:
Robert C. Gorman,
Robert C. Gorman
University of Pennsylvania School of Medicine, Philadelphia, PA
Search for other works by this author on:
Joseph H. Gorman
Joseph H. Gorman
University of Pennsylvania School of Medicine, Philadelphia, PA
Search for other works by this author on:
Brett Zubiate
University of Pittsburgh, Pittsburgh, PA
Michael Sacks
University of Pittsburgh, Pittsburgh, PA
Robert C. Gorman
University of Pennsylvania School of Medicine, Philadelphia, PA
Joseph H. Gorman
University of Pennsylvania School of Medicine, Philadelphia, PA
Paper No:
SBC2007-176752, pp. 247-248; 2 pages
Published Online:
March 12, 2014
Citation
Zubiate, B, Sacks, M, Gorman, RC, & Gorman, JH. "In Vivo Dynamic Strains of the Mitral Valve Annulus." Proceedings of the ASME 2007 Summer Bioengineering Conference. ASME 2007 Summer Bioengineering Conference. Keystone, Colorado, USA. June 20–24, 2007. pp. 247-248. ASME. https://doi.org/10.1115/SBC2007-176752
Download citation file:
8
Views
Related Proceedings Papers
Related Articles
Computational Modeling of Inertial Effects on Electromechanics of the Heart
J. Comput. Nonlinear Dynam (October,2019)
A Comparison of Uniaxial and Biaxial Mechanical Properties of the Annulus Fibrosus: A Porcine Model
J Biomech Eng (February,2011)
The Impact of Cardiac Motion on Aortic Valve Flow Used in Computational Simulations of the Thoracic Aorta
J Biomech Eng (September,2016)
Related Chapters
Introduction and Definitions
Handbook on Stiffness & Damping in Mechanical Design
Introduction
Ultrasonic Methods for Measurement of Small Motion and Deformation of Biological Tissues for Assessment of Viscoelasticity
Introduction and Scope
High Frequency Piezo-Composite Micromachined Ultrasound Transducer Array Technology for Biomedical Imaging