While there are many factors that should be considered when determining if a stud can be reused, one of them is the nut factor. The study described in this paper set out to determine if the nut factor of a Xylan 1424 coated stud is significantly affected by the age of the coating and/or the cycles of tightening. A load cell was used to compare the nut factor: 1) of previously installed (used) studs to new studs, 2) of a new and used stud that were tightened more than once, and 3) associated with the first tightening pass to subsequent passes for a new stud. The results show that the age of the stud and the amount it has been tightened contribute to an increased nut factor for used Xylan 1424 studs.
Volume Subject Area:
Design and Analysis
This content is only available via PDF.
Copyright © 2019 by ASME