This report documents the results of two of tests that were performed on an explosive containment vessel at Sandia National Laboratories in Albuquerque, New Mexico in July 2013 to provide some deeper understanding of the effects of charge geometry on the vessel response [1]. The vessel was fabricated under Code Case 2564 of the ASME Boiler and Pressure Vessel Code, which provides rules for the design of impulsively loaded vessels [2]. The explosive rating for the vessel, based on the Code Case, is nine (9) pounds TNT-equivalent. One explosive test consisted of a single, centrally located, 7.2 pound bare charge of Composition C-4 (equivalent to 9 pounds TNT). The other test used six each 1.2 pound charges of Composition C-4 (7.2 pounds total) distributed in two bays of three.