Flow Accelerated Corrosion (FAC) is a pipe wall thinning phenomenon to be monitored and managed in power plants with high priority. In Japan, its management has been conducted with conservative evaluation of thinning rate and residual lifetime of the piping based on wall thickness measurements. However, noticeable case of the wall thinning occurred at separation and union pipe. In such pipe system, it is a problem to manage a section beneath reinforcing plate of T-tube pipe and a crotch of T-joint pipe; wall thickness measurement with high accuracy is difficult to conduct in the region by using ordinary ultrasonic testing devices. In this study, numerical analysis for separation and union parts of T-tube and T-joint pipes was conducted, and wall thinning profile by FAC was evaluated by calculating mass transfer coefficient and geometry factor. Based on these results, applicable wall thinning management for T-tube and T-joint pipes was considered. In the case of union flow from main and branch pipe, the wall thinning profile of T-tube showed the tendency of increase at main pipe like semielliptical region. On the other hand, noticeable profile appeared at crotch in T-joint although it was found that geometry factor of T-joint in this flow pattern was half the value of T-tube. An alternative evaluation method to previous one might be needed for such semielliptical region in T-tube and crotch in T-joint.
Skip Nav Destination
ASME 2014 Pressure Vessels and Piping Conference
July 20–24, 2014
Anaheim, California, USA
Conference Sponsors:
- Pressure Vessels and Piping Division
ISBN:
978-0-7918-4603-2
PROCEEDINGS PAPER
Numerical Evaluation of Wall Thinning Profile in Separation and Union Pipe due to Flow Accelerated Corrosion
Shun Watanabe,
Shun Watanabe
Central Research Institute of Electric Power Industry, Komae, Tokyo, Japan
Search for other works by this author on:
Kimitoshi Yoneda
Kimitoshi Yoneda
Central Research Institute of Electric Power Industry, Komae, Tokyo, Japan
Search for other works by this author on:
Shun Watanabe
Central Research Institute of Electric Power Industry, Komae, Tokyo, Japan
Kimitoshi Yoneda
Central Research Institute of Electric Power Industry, Komae, Tokyo, Japan
Paper No:
PVP2014-28058, V06AT06A070; 9 pages
Published Online:
November 18, 2014
Citation
Watanabe, S, & Yoneda, K. "Numerical Evaluation of Wall Thinning Profile in Separation and Union Pipe due to Flow Accelerated Corrosion." Proceedings of the ASME 2014 Pressure Vessels and Piping Conference. Volume 6A: Materials and Fabrication. Anaheim, California, USA. July 20–24, 2014. V06AT06A070. ASME. https://doi.org/10.1115/PVP2014-28058
Download citation file:
12
Views
Related Proceedings Papers
Related Articles
Failure Pressure in Corroded Pipelines Based on Equivalent Solutions for Undamaged Pipe
J. Pressure Vessel Technol (October,2010)
Flow and Mass Transfer in Bends Under Flow-Accelerated Corrosion Wall Thinning Conditions
J. Eng. Gas Turbines Power (January,2011)
The Impact of Probabilistic Modeling in Life-Cycle Management of Nuclear Piping Systems
J. Eng. Gas Turbines Power (January,2011)
Related Chapters
Operability and Functionality Qualification
Continuing and Changing Priorities of the ASME Boiler & Pressure Vessel Codes and Standards
Features That Should Make Selections Unacceptable
Heat Exchanger Engineering Techniques
Examination
Process Piping: The Complete Guide to ASME B31.3, Fourth Edition