Full structural weld overlays (FSWOLs) have been used extensively as a repair/mitigation technique for primary water stress corrosion cracking (PWSCC) in pressurizer nozzle dissimilar metal (DM) welds. To support an approved FSWOL design and safety submission for British Energy pressurized water reactor (PWR) nozzles, an in-depth evaluation was performed to assess the effects of a FSWOL on the through-wall residual stress distribution in safety/relief pressurizer nozzles. Two safety/relief pressurizer nozzle mockups were fabricated based on British Energy’s PWR nozzle design. One mockup included the nozzle to safe-end DM weld and the safe-end to stainless steel weld while the second mockup included the DM weld, the stainless steel weld and a Westinghouse-designed structural weld overlay. The mockups were fabricated utilizing materials and techniques that represented the plant-specific nozzles as closely as possible and detailed welding parameters were recorded during fabrication. All welds were subsequently nondestructively evaluated (NDE). A thorough review of the detailed fabrication records and the NDE results was performed and several circumferential positions were selected on each mockup for subsequent residual stress measurement. The through-wall residual stress profiles were experimentally measured through the DM weld centerline at the selected circumferential positions using both the deep hole drilling (DHD) and incremental deep hole drilling (iDHD) measurement techniques. In addition to experimental residual stress measurements, the through-wall residual stress profiles were simulated using a 2-D axisymmetric ANSYS™ finite element (FE) model. The model utilized kinematic strain hardening and the temperature constraint method which greatly simplified the simulation as compared to detailed heat source modeling methods. A range of residual weld stress profiles was calculated by varying the time at which the temperature constraints were applied to the model. The simulation results were compared to the measurement results. It was found that the effects of the FSWOL were principally three fold. Specifically, the FSWOL causes a much deeper compressive stress field, i.e., the overlay shifts tension out towards the outside diameter surface. Further, the FSWOL reduces tension in the underlying dissimilar metal weld, and finally, the FSWOL causes higher peak compressive and tensile residual stresses, both of which move deeper into the nozzle wall after the overlay is applied. Relatively good agreement was observed between the FE results and the measurements results.
Skip Nav Destination
ASME 2010 Pressure Vessels and Piping Division/K-PVP Conference
July 18–22, 2010
Bellevue, Washington, USA
Conference Sponsors:
- Pressure Vessels and Piping Division
ISBN:
978-0-7918-49255
PROCEEDINGS PAPER
Simulation and Measurement of Through-Wall Residual Stresses in a Structural Weld Overlaid Pressurizer Nozzle
Stephen Marlette,
Stephen Marlette
Westinghouse Electric Company LLC, Pittsburgh, PA
Search for other works by this author on:
Paula Freyer,
Paula Freyer
Westinghouse Electric Company LLC, Pittsburgh, PA
Search for other works by this author on:
Michael Smith,
Michael Smith
British Energy, Gloucester, UK
Search for other works by this author on:
Andrew Goodfellow,
Andrew Goodfellow
British Energy, Gloucester, UK
Search for other works by this author on:
Xavier Pitoiset,
Xavier Pitoiset
Westinghouse Electric Belgium SA, Nivelles, Belgium
Search for other works by this author on:
Bradley Voigt,
Bradley Voigt
WEC Welding & Machining LLC, Lake Bluff, IL
Search for other works by this author on:
Rick Rishel,
Rick Rishel
WesDyne International, Madison, PA
Search for other works by this author on:
Ed Kingston
Ed Kingston
Veqter Ltd., Bristol, UK
Search for other works by this author on:
Stephen Marlette
Westinghouse Electric Company LLC, Pittsburgh, PA
Paula Freyer
Westinghouse Electric Company LLC, Pittsburgh, PA
Michael Smith
British Energy, Gloucester, UK
Andrew Goodfellow
British Energy, Gloucester, UK
Xavier Pitoiset
Westinghouse Electric Belgium SA, Nivelles, Belgium
Bradley Voigt
WEC Welding & Machining LLC, Lake Bluff, IL
Rick Rishel
WesDyne International, Madison, PA
Ed Kingston
Veqter Ltd., Bristol, UK
Paper No:
PVP2010-25736, pp. 1425-1433; 9 pages
Published Online:
January 10, 2011
Citation
Marlette, S, Freyer, P, Smith, M, Goodfellow, A, Pitoiset, X, Voigt, B, Rishel, R, & Kingston, E. "Simulation and Measurement of Through-Wall Residual Stresses in a Structural Weld Overlaid Pressurizer Nozzle." Proceedings of the ASME 2010 Pressure Vessels and Piping Division/K-PVP Conference. ASME 2010 Pressure Vessels and Piping Conference: Volume 6, Parts A and B. Bellevue, Washington, USA. July 18–22, 2010. pp. 1425-1433. ASME. https://doi.org/10.1115/PVP2010-25736
Download citation file:
13
Views
Related Proceedings Papers
Related Articles
Residual Stress Measurement in 304 Stainless Steel Weld Overlay Pipes
J. Eng. Mater. Technol (January,1996)
Effect of Ultrasonic Impact Treatment on the Stress Corrosion Cracking of 304 Stainless Steel Welded Joints
J. Pressure Vessel Technol (October,2009)
Evaluation of the Integrity of PWR Bimetallic Welds
J. Pressure Vessel Technol (August,2000)
Related Chapters
Development of Nuclear Boiler and Pressure Vessels in Taiwan
Companion Guide to the ASME Boiler and Pressure Vessel Code, Volume 3, Third Edition
Overview of Section XI Stipulations
Companion Guide to the ASME Boiler and Pressure Vessel Code, Volume 2, Third Edition
Subsection NE—Class MC Components
Companion Guide to the ASME Boiler & Pressure Vessel Codes, Volume 1 Sixth Edition