Since the 1970s power uprates have been employed to enhance the electricity output of nuclear power plants. Extended power uprate is defined as an increase of reactor thermal power in excess of 7% up to about 20% of the original plant licensed thermal power. Such power uprates generally require significant modification of major plant equipment and were initially implemented at boiling water reactor plants approximately 15 years ago. The early experience with extended power uprates was very positive. However, in recent years an increased number of failures of nuclear power plant components totally or partly caused by those power uprates have been reported. This paper presents the issues and operating experience with extended power uprate at the Leibstadt Boiling Water Reactor Nuclear Power Plant in Switzerland concerning the mechanical and electrical equipment. Failures such as fretting-wear and fatigue damage due to an increased vibration level, structural damage due to thermal overheating as well as shortened maintenance intervals due to elevated temperature and increased pump speed are reported. As a summary, the failures of mechanical and electrical components caused by extended power uprate experienced at the plant during the last years are related to plant reliability and have not adversely impacted plant safety.
Skip Nav Destination
ASME 2008 Pressure Vessels and Piping Conference
July 27–31, 2008
Chicago, Illinois, USA
Conference Sponsors:
- Pressure Vessels and Piping
ISBN:
978-0-7918-4830-2
PROCEEDINGS PAPER
Experience With Extended Power Uprate at Leibstadt Nuclear Power Plant
Robert Engel,
Robert Engel
Kernkraftwerk Leibstadt AG, Leibstadt, Switzerland
Search for other works by this author on:
Karl Zichanowicz
Karl Zichanowicz
Kernkraftwerk Leibstadt AG, Leibstadt, Switzerland
Search for other works by this author on:
Robert Engel
Kernkraftwerk Leibstadt AG, Leibstadt, Switzerland
Karl Zichanowicz
Kernkraftwerk Leibstadt AG, Leibstadt, Switzerland
Paper No:
PVP2008-61020, pp. 71-78; 8 pages
Published Online:
July 24, 2009
Citation
Engel, R, & Zichanowicz, K. "Experience With Extended Power Uprate at Leibstadt Nuclear Power Plant." Proceedings of the ASME 2008 Pressure Vessels and Piping Conference. Volume 7: Operations, Applications and Components. Chicago, Illinois, USA. July 27–31, 2008. pp. 71-78. ASME. https://doi.org/10.1115/PVP2008-61020
Download citation file:
10
Views
Related Proceedings Papers
Related Articles
Improving Nuclear Power Plant's Operational Efficiencies in the U.S.A.
Mechanical Engineering (January,2011)
Dielectric Breakdown Properties of Thermosetting Laminates
Trans. ASME (July,1955)
A Rubbery Cure Shrinkage Model for Analyzing Encapsulated Assemblies
J. Electron. Packag (September,1995)
Related Chapters
Lessons Learned: NRC Experience
Continuing and Changing Priorities of the ASME Boiler & Pressure Vessel Codes and Standards
Development of Nuclear Boiler and Pressure Vessels in Taiwan
Companion Guide to the ASME Boiler and Pressure Vessel Code, Volume 3, Third Edition
Fatigue Verification and Nonlinear Alternatives
Toward Consistent Design Evaluation of Nuclear Power Piping by Nonlinear Finite Element Analysis