Severe furnace vibration developed in a gas-fired package boiler during initial operation. The vibration occurred at higher loads and was characterized by an acoustic standing wave residing inside the furnace in the front-to-rear direction along burner axis. Theoretical predictions indicated that the thermoacoustic behavior of the burner/furnace system operated in an unstable range explaining the underlying cause of the vibration problem. For the elimination of the vibration problem, a two-step solution was utilized: 1. The mode of fuel injection was modified with the aim of disrupting the interface between the hot furnace gases and the cold burner air region in order to minimize the principal thermoacoustic hot-to-cold driving mechanism. This step was successful in mitigating the vibration in a still thermoacoustically unstable system. 2. A full elimination of the vibration was achieved by making the system thermoacoustically stable by modifying the cold air portion of the system. Both, the step 1 solution which suppressed the thermoacoustic excitation source and the step 2 solution of making the system thermoacoustially stable allowed the boiler to operate without vibration at all loads. The paper gives a detailed description of the issues involved.
Skip Nav Destination
ASME 2008 Pressure Vessels and Piping Conference
July 27–31, 2008
Chicago, Illinois, USA
Conference Sponsors:
- Pressure Vessels and Piping
ISBN:
978-0-7918-4827-2
PROCEEDINGS PAPER
Elimination of Thermoacoustic Furnace Vibration in a Gas-Fired Package Boiler: A Case Study
Frantisek L. Eisinger,
Frantisek L. Eisinger
Foster Wheeler North America, Inc., Clinton, NJ
Search for other works by this author on:
Robert E. Sullivan
Robert E. Sullivan
Foster Wheeler North America, Inc., Clinton, NJ
Search for other works by this author on:
Frantisek L. Eisinger
Foster Wheeler North America, Inc., Clinton, NJ
Robert E. Sullivan
Foster Wheeler North America, Inc., Clinton, NJ
Paper No:
PVP2008-61209, pp. 377-383; 7 pages
Published Online:
July 24, 2009
Citation
Eisinger, FL, & Sullivan, RE. "Elimination of Thermoacoustic Furnace Vibration in a Gas-Fired Package Boiler: A Case Study." Proceedings of the ASME 2008 Pressure Vessels and Piping Conference. Volume 4: Fluid-Structure Interaction. Chicago, Illinois, USA. July 27–31, 2008. pp. 377-383. ASME. https://doi.org/10.1115/PVP2008-61209
Download citation file:
13
Views
Related Proceedings Papers
Related Articles
Elimination of Thermoacoustic Furnace Vibration in a Gas-Fired Package Boiler: A Case Study
J. Pressure Vessel Technol (June,2009)
Prediction of Thermoacoustic Vibration of Burner/Furnace Systems in Utility Boilers
J. Pressure Vessel Technol (February,2008)
Prediction of Performance From PRB Coal Fired in Utility Boilers With Various Furnace and Firing System Arrangements
J. Eng. Gas Turbines Power (December,2010)
Related Chapters
Combined Cycle Power Plant
Energy and Power Generation Handbook: Established and Emerging Technologies
Fluidelastic Instability of Tube Bundles in Single-Phase Flow
Flow-Induced Vibration Handbook for Nuclear and Process Equipment
Random Turbulence Excitation in Single-Phase Flow
Flow-Induced Vibration Handbook for Nuclear and Process Equipment