The Quad Cities Nuclear Power Station, Units 1 and 2, have a history of steam line vibration issues. The implementation of an Extended Power Uprate resulted in significant increases in steam line vibration as well as acoustic loading of the steam dryers, which led to equipment failures and fatigue cracking of the dryers. This paper discusses the extensive data collection on the Quad Cities Unit 2 replacement dryer and the Main Steam Lines. This data was taken with the intent of identifying acoustic sources in the steam system. Review of the data confirmed that vortex shedding coupled column resonance in the relief and safety valve standpipes were the principal sources of large magnitude acoustic loads in the main steam system. Modifications were developed in subscale testing to alter the acoustic properties of the valve standpipes and add acoustic damping to the system. The modifications developed and installed consisted of acoustic side branches that were attached to the Electromatic Relief Valve (ERV) and Main Steam Safety Valve (MSSV) attachment pipes. Subsequent post-modification testing was performed in plant to confirm the effectiveness of the modifications. The modifications have demonstrated a reduction in the acoustic pressure loads at full Extended Power Uprate (EPU) conditions to levels below those at Original Licensed Thermal Power (OLTP).
Skip Nav Destination
ASME 2007 Pressure Vessels and Piping Conference
July 22–26, 2007
San Antonio, Texas, USA
Conference Sponsors:
- Pressure Vessels and Piping Division
ISBN:
0-7918-4282-7
PROCEEDINGS PAPER
Identification of Quad Cities Main Steam Line Acoustic Sources and Vibration Reduction
Kevin Ramsden,
Kevin Ramsden
Exelon Nuclear, Warrenville, IL
Search for other works by this author on:
Roman Gesior,
Roman Gesior
Exelon Nuclear, Warrenville, IL
Search for other works by this author on:
Brian Strub
Brian Strub
Exelon Nuclear, Warrenville, IL
Search for other works by this author on:
Guy DeBoo
Exelon Nuclear, Warrenville, IL
Kevin Ramsden
Exelon Nuclear, Warrenville, IL
Roman Gesior
Exelon Nuclear, Warrenville, IL
Brian Strub
Exelon Nuclear, Warrenville, IL
Paper No:
PVP2007-26658, pp. 485-491; 7 pages
Published Online:
August 20, 2009
Citation
DeBoo, G, Ramsden, K, Gesior, R, & Strub, B. "Identification of Quad Cities Main Steam Line Acoustic Sources and Vibration Reduction." Proceedings of the ASME 2007 Pressure Vessels and Piping Conference. Volume 4: Fluid-Structure Interaction. San Antonio, Texas, USA. July 22–26, 2007. pp. 485-491. ASME. https://doi.org/10.1115/PVP2007-26658
Download citation file:
22
Views
Related Proceedings Papers
Related Articles
Flow-Induced Vibration in Safety Relief Valves
J. Pressure Vessel Technol (August,1986)
Control of Steam Venting Noise in Power Plants
J. Eng. Power (April,1978)
Fire Versus Non-Fire Contingencies: A Study of Pressure-Relief Device Sizing Risks
J. Pressure Vessel Technol (February,2006)
Related Chapters
Lessons Learned: NRC Experience
Continuing and Changing Priorities of the ASME Boiler & Pressure Vessel Codes and Standards
Development of Nuclear Boiler and Pressure Vessels in Taiwan
Companion Guide to the ASME Boiler and Pressure Vessel Code, Volume 3, Third Edition
A PSA Update to Reflect Procedural Changes (PSAM-0217)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)