During the normal cycle of a pressurized water reactor, boron concentration is reduced in the core until fuel burns up. A stretch out of the normal cycle is however possible afterwards, provided primary coolant temperature is reduced. In those stretch out periods, nuclear operators want to keep constant thermal power exchanged in the steam generator, in order to preserve its performances. Under that constraint, the required reduction in primary coolant temperature involves both a decrease of secondary cooling system pressure and an increase of tube bundle vibrations. Since neither pressure nor vibrations should exceed some given thresholds in order to preserve component integrity, the reduction of primary coolant temperature has to be limited. Nuclear plant operators thereafter need an operating diagram, i.e. a diagram that provides minimum allowed primary coolant temperature versus power rate. In that context, we propose a method to derive such a diagram, by combining, on the one hand a code for simulating primary and secondary fluid flows in steam generators and, on the other hand, a software that allows one to predict fluid elastic tube bundle instabilities. That method allows one to take into account both tube fouling and plugging. It is now used by French utility “Electricite´ De France”, in order to check or supplement the analysis that are provided by steam generator manufacturers.
Skip Nav Destination
ASME 2006 Pressure Vessels and Piping/ICPVT-11 Conference
July 23–27, 2006
Vancouver, BC, Canada
Conference Sponsors:
- Pressure Vessels and Piping Division
ISBN:
0-7918-4755-1
PROCEEDINGS PAPER
Influence of Steam Generator Tube Bundle Vibrations on the Operating Diagram of a Nuclear Plant During Stretch Out Available to Purchase
Andre´ Adobes,
Andre´ Adobes
Electricite´ De France, Chatou, France
Search for other works by this author on:
Joe¨l Pillet,
Joe¨l Pillet
Electricite´ De France, Chatou, France
Search for other works by this author on:
Franck David,
Franck David
Electricite´ De France, Chatou, France
Search for other works by this author on:
Michae¨l Gaudin
Michae¨l Gaudin
Electricite´ De France, Villeurbanne, France
Search for other works by this author on:
Andre´ Adobes
Electricite´ De France, Chatou, France
Joe¨l Pillet
Electricite´ De France, Chatou, France
Franck David
Electricite´ De France, Chatou, France
Michae¨l Gaudin
Electricite´ De France, Villeurbanne, France
Paper No:
PVP2006-ICPVT-11-93239, pp. 147-156; 10 pages
Published Online:
July 23, 2008
Citation
Adobes, A, Pillet, J, David, F, & Gaudin, M. "Influence of Steam Generator Tube Bundle Vibrations on the Operating Diagram of a Nuclear Plant During Stretch Out." Proceedings of the ASME 2006 Pressure Vessels and Piping/ICPVT-11 Conference. Volume 4: Fluid Structure Interaction, Parts A and B. Vancouver, BC, Canada. July 23–27, 2006. pp. 147-156. ASME. https://doi.org/10.1115/PVP2006-ICPVT-11-93239
Download citation file:
6
Views
Related Proceedings Papers
Related Articles
Simulation of Cooling Systems in Gas Turbines
J. Turbomach (April,1996)
Experimental Testing of Gerotor and Scroll Expanders Used in, and Energetic and Exergetic Modeling of, an Organic Rankine Cycle
J. Energy Resour. Technol (March,2009)
Combining RAVEN, RELAP5-3D, and PHISICS for Fuel Cycle and Core Design Analysis for New Cladding Criteria
ASME J of Nuclear Rad Sci (April,2017)
Related Chapters
Development of Nuclear Boiler and Pressure Vessels in Taiwan
Companion Guide to the ASME Boiler and Pressure Vessel Code, Volume 3, Third Edition
Hydrodynamic Mass, Natural Frequencies and Mode Shapes
Flow-Induced Vibration Handbook for Nuclear and Process Equipment
Scope of Section I, Organization, and Service Limits
Power Boilers: A Guide to the Section I of the ASME Boiler and Pressure Vessel Code, Second Edition