During the 2003 Tokachi-oki, Japan earthquake, many oil tanks located in Tomakomai were damaged by sloshing due to the long-period strong ground motion. It is especially noted that the single-deck floating-roofs of seven tanks collapsed as they sank with the buckling failure of the pontoons, which resulted in fire accidents of two tanks. To clarify the cause of such damages, it is necessary to investigate in detail the sloshing behaviors in consideration of the existence of a floating-roof. However, so far most of the researches on sloshing have treated only the case of a free surface or the case of a rigid floating-roof, and have not considered the case of an elastic floating-roof, which is used in an actual tank. In this paper, the authors discuss the problem on the basis of fluid-elastic vibration analysis, that is, they investigate the sloshing behaviors of actual floating-roof models with single-deck type and double-deck type and indicate several important viewpoints on the seismic design which has hardly been taken into account hitherto.
Skip Nav Destination
ASME 2006 Pressure Vessels and Piping/ICPVT-11 Conference
July 23–27, 2006
Vancouver, BC, Canada
Conference Sponsors:
- Pressure Vessels and Piping Division
ISBN:
0-7918-4755-1
PROCEEDINGS PAPER
Fluid-Elastic Analysis and Design of Sloshing in Floating-Roof Tanks Subjected to Earthquake Motions Available to Purchase
Fujikazu Sakai,
Fujikazu Sakai
FS Technology, Inc., Tokyo, Japan
Search for other works by this author on:
Ryousuke Inoue,
Ryousuke Inoue
Ibaraki University, Ibaraki, Japan
Search for other works by this author on:
Shoichiro Hayashi
Shoichiro Hayashi
Kawasaki Heavy Industries, Ltd., Hyogo, Japan
Search for other works by this author on:
Fujikazu Sakai
FS Technology, Inc., Tokyo, Japan
Ryousuke Inoue
Ibaraki University, Ibaraki, Japan
Shoichiro Hayashi
Kawasaki Heavy Industries, Ltd., Hyogo, Japan
Paper No:
PVP2006-ICPVT-11-93622, pp. 1437-1446; 10 pages
Published Online:
July 23, 2008
Citation
Sakai, F, Inoue, R, & Hayashi, S. "Fluid-Elastic Analysis and Design of Sloshing in Floating-Roof Tanks Subjected to Earthquake Motions." Proceedings of the ASME 2006 Pressure Vessels and Piping/ICPVT-11 Conference. Volume 4: Fluid Structure Interaction, Parts A and B. Vancouver, BC, Canada. July 23–27, 2006. pp. 1437-1446. ASME. https://doi.org/10.1115/PVP2006-ICPVT-11-93622
Download citation file:
14
Views
Related Articles
Internal Resonance of a Floating Roof Subjected to Nonlinear Sloshing
J. Appl. Mech (January,2010)
Vibration Analysis of a Floating Roof Subjected to Radial Second Mode of Sloshing
J. Pressure Vessel Technol (April,2010)
Elliptical Deformation of a Floating Roof Pontoon Due to Radial Second Mode of Sloshing (Effect of the Geometry of Pontoon Cross-Section on the Hoop Membrane Stress)
J. Pressure Vessel Technol (October,2011)
Related Chapters
Modeling of SAMG Operator Actions in Level 2 PSA (PSAM-0164)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)
Use of PSA in Lisencing of EPR 1600 in Finland (PSAM-0160)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)
Pipeline Integrity and Security
Continuing and Changing Priorities of the ASME Boiler & Pressure Vessel Codes and Standards