The steam generator in a nuclear power plant is a large heat exchanger that uses heat from reactor to generate steam to drive the turbine generators. Rupture of a steam generator tube can result in release of fission products to environment. Therefore, an accurate integrity assessment of the steam generator tubes with cracks is of great importance for maintaining safety of a nuclear power plant. The steam generator tubes are supported at periodic intervals by support plates and rotations of the tubes are constrained. Although it was reported that the limit load for a circumferential crack was significantly affected by boundary condition of the tube, existing limit load solutions do not include the constraining effect of tube supports. This paper provides detailed limit load solutions for circumferential cracks in steam generator tubes considering the actual boundary conditions to simulate the constraining effect of the tube supports. Such solutions are developed based on three dimensional (3D) finite element analyses. The resulting limit load solutions are given in a polynomial form, and thus can be simply used in practical integrity assessment of the steam generator tubes.
Skip Nav Destination
ASME 2005 Pressure Vessels and Piping Conference
July 17–21, 2005
Denver, Colorado, USA
Conference Sponsors:
- Pressure Vessels and Piping Division
ISBN:
0-7918-4188-X
PROCEEDINGS PAPER
Assessment of Limit Loads for Circumferential Cracks in Steam Generator Tube Considering Constraining Effect of Tube Support Available to Purchase
Hyun Su Kim,
Hyun Su Kim
Korea Power Engineering Company, Youngin, Korea
Search for other works by this author on:
Jong Sung Kim,
Jong Sung Kim
Korea Power Engineering Company, Youngin, Korea
Search for other works by this author on:
Tae Eun Jin,
Tae Eun Jin
Korea Power Engineering Company, Youngin, Korea
Search for other works by this author on:
Hong Deok Kim,
Hong Deok Kim
Korea Electric Power Research Institute, Daejeon, Korea
Search for other works by this author on:
Han Sub Chung
Han Sub Chung
Korea Electric Power Research Institute, Daejeon, Korea
Search for other works by this author on:
Hyun Su Kim
Korea Power Engineering Company, Youngin, Korea
Jong Sung Kim
Korea Power Engineering Company, Youngin, Korea
Tae Eun Jin
Korea Power Engineering Company, Youngin, Korea
Hong Deok Kim
Korea Electric Power Research Institute, Daejeon, Korea
Han Sub Chung
Korea Electric Power Research Institute, Daejeon, Korea
Paper No:
PVP2005-71308, pp. 363-368; 6 pages
Published Online:
July 29, 2008
Citation
Kim, HS, Kim, JS, Jin, TE, Kim, HD, & Chung, HS. "Assessment of Limit Loads for Circumferential Cracks in Steam Generator Tube Considering Constraining Effect of Tube Support." Proceedings of the ASME 2005 Pressure Vessels and Piping Conference. Volume 3: Design and Analysis. Denver, Colorado, USA. July 17–21, 2005. pp. 363-368. ASME. https://doi.org/10.1115/PVP2005-71308
Download citation file:
6
Views
Related Proceedings Papers
Related Articles
A Spectral Finite Element Model for Wave Propagation Analysis in Laminated Composite Plate
J. Vib. Acoust (August,2006)
Dual Receiver Concept for Solar Towers up to 100 MW
J. Sol. Energy Eng (August,2006)
Reliability of Steam Generator Tubes With Axial Cracks
J. Pressure Vessel Technol (November,1996)
Related Chapters
PSA Level 2 — NPP Ringhals 2 (PSAM-0156)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)
Lessons Learned: NRC Experience
Continuing and Changing Priorities of the ASME Boiler & Pressure Vessel Codes and Standards
Insights and Results of the Shutdown PSA for a German SWR 69 Type Reactor (PSAM-0028)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)