The Seismic Proving Test of Heavy Component with Energy Absorbing Support has been conducted to prove the reliability of advanced seismic technology, supporting heavy component such as PWR Steam Generator with large capacity energy absorbing supports. This paper introduces the result of the proving test, using 1/2.5 scale model of PWR Steam Generator supported by Lead Extrusion Damper (LED), conducted on 2000–2001. This project has been conducted by the Nuclear Power Engineering Corporation (NUPEC) since 1995, using a large-scale, high-performance shaking table at Tadotsu Engineering Laboratory under the sponsorship of the Ministry of Economy Trade and Industry. Up to 2.9 S2 (extreme design earthquake), LED showed stable energy absorbing performance and Steam Generator- primary piping system indicate no meaningful damage.
Skip Nav Destination
ASME 2002 Pressure Vessels and Piping Conference
August 5–9, 2002
Vancouver, BC, Canada
Conference Sponsors:
- Pressure Vessels and Piping Division
ISBN:
0-7918-4656-3
PROCEEDINGS PAPER
Seismic Proving Test of Heavy Component With Energy Absorbing Support: Proving Test Results
M. Konno,
M. Konno
Nuclear Power Engineering Corporation, Tokyo, Japan
Search for other works by this author on:
H. Abe,
H. Abe
Nuclear Power Engineering Corporation, Tokyo, Japan
Search for other works by this author on:
K. Kuroda,
K. Kuroda
Nuclear Power Engineering Corporation, Tokyo, Japan
Search for other works by this author on:
K. Tai,
K. Tai
Mitsubishi Heavy Industries, Ltd., Takasago-City, Japan
Search for other works by this author on:
H. Sumiya
H. Sumiya
Mitsubishi Heavy Industries, Ltd., Kobe, Japan
Search for other works by this author on:
T. Iwatsubo
Kobe University, Kobe, Japan
M. Konno
Nuclear Power Engineering Corporation, Tokyo, Japan
H. Abe
Nuclear Power Engineering Corporation, Tokyo, Japan
K. Kuroda
Nuclear Power Engineering Corporation, Tokyo, Japan
K. Tai
Mitsubishi Heavy Industries, Ltd., Takasago-City, Japan
H. Sumiya
Mitsubishi Heavy Industries, Ltd., Kobe, Japan
Paper No:
PVP2002-1404, pp. 107-111; 5 pages
Published Online:
August 14, 2008
Citation
Iwatsubo, T, Konno, M, Abe, H, Kuroda, K, Tai, K, & Sumiya, H. "Seismic Proving Test of Heavy Component With Energy Absorbing Support: Proving Test Results." Proceedings of the ASME 2002 Pressure Vessels and Piping Conference. Seismic Engineering, Volume 1. Vancouver, BC, Canada. August 5–9, 2002. pp. 107-111. ASME. https://doi.org/10.1115/PVP2002-1404
Download citation file:
7
Views
Related Proceedings Papers
ACR-1000™ Level 1 PSA Summary
ICONE17
Related Articles
Evaluation of Aseismic Reliability of Actual Boiler Structures and a Study on Design of Seismic Ties Based on Proof Tests Using a Large Scaled Shaking Table
J. Pressure Vessel Technol (February,2004)
An Experimental Study on the Seismic Response of Base-Isolated Secondary Systems
J. Pressure Vessel Technol (February,2002)
Design of 1000-MW Steam Turbine-Generator Unit for Ravenswood No 3
J. Eng. Power (April,1964)
Related Chapters
Importance of Effective Monitoring
Consensus on Operating Practices for the Sampling and Monitoring of Feedwater and Boiler Water Chemistry in Modern Industrial Boilers (CRTD-81)
Lessons Learned: NRC Experience
Continuing and Changing Priorities of the ASME Boiler & Pressure Vessel Codes and Standards
Piping Design
Power Boilers: A Guide to the Section I of the ASME Boiler and Pressure Vessel Code, Second Edition