Heat exchangers, which cool boiler flue gas to temperatures below the water vapor dew point, can be used to capture moisture from flue gas and reduce external water consumption for power plant operations. At the same time, thermal energy removed from the flue gas can be used to improve unit heat rate. Recent data also show that emissions of air toxics from flue gas would be reduced by use of condensing heat exchangers. This paper describes results from a slip stream test of a water cooled condensing heat exchanger system at a power plant with a lignite-fired boiler. The flue gas which flowed through the heat exchangers had been extracted from a duct downstream of the electrostatic precipitator. Measurements were made of flue gas and cooling water temperatures, flue gas water vapor concentrations, and concentrations of elemental and oxidized Hg at the inlet and exit of the heat exchanger system. Condensed water was also collected and analyzed for concentrations of H2SO4 and HCl. Results on the effects of the condensing heat exchanger operating conditions on oxidation and capture of Hg and on the capture of sulfuric and hydrochloric acids are described.